EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Next-Generation Wastewater-Based Epidemiology: Green Automation for Detecting 69 Multiclass Pharmaceutical and Personal Care Products in Wastewater Using 96-Well Plate Solid-Phase Extraction by LC-MS/MS

Bhaskar Karubothula iD, Veera Venkataramana Kota, Dnyaneshwar Shinde iD, Raghu Tadala iD, Vishnu Cheerala, Samara Bin Salem, Wael Faroug Elamin iD, Grzegorz Brudecki

Molecules · 2025

DOI: 10.3390/molecules30183694 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Molecules, 2025. Verfasst von Bhaskar Karubothula und 7 weiteren Autor:innen. Beteiligte Einrichtung: RASID Laboratory of Abu Dhabi Quality & Conformity Council (ADQCC) & M42 Environmental Sciences, Abu Dhabi P.O. Box 853, United Arab Emirates. Hauptthemen laut MEDLINE: Solid Phase Extraction, Wastewater, Water Pollutants, Chemical, Cosmetics. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Conventional methods for detecting pharmaceutical and personal care products (PPCPs) in environmental samples are complex, resource-intensive, and not sustainable. Therefore, this study aimed to evaluate an automated sample preparation approach using the Biomek i7 Workstation to analyze 69 PPCPs in wastewater, with the objective to improve monitoring of public health and environmental protection. The method underwent extensive development, including optimization of UPLC-MS/MS parameters, preparation of wastewater matrix blank sample and assessment of extraction efficiency using three types of SPE cartridges. Extraction efficiency trials revealed that the order of suitability for SPE cartridges is Mixed-Mode Anion Exchange (MAX) > Mixed-Mode Cation Exchange (MCX) > Hydrophilic–Lipophilic Balance (HLB). The method demonstrated specificity for all targeted PPCPs, with the max interfering peak for 1, 7 Dimethylxanthine reaching 14.79% of the response at the target limit of quantification (LOQ). The method met ±20% matrix effect tolerance for 63 PPCPs, while 6 PPCPs showed signal enhancement. The 8-point procedural calibration curve prepared using automated robotic extraction has demonstrated linearity across the tested range. A spiking study at low (LQC), medium (MQC), and high (HQC) quality control levels (n = 6), repeated on three separate occasions, showed % RSD values within 20% and % recovery between 80 and 120%. The method met validation requirements, showed reliability in Intra-Laboratory Comparison, Blind Testing (BT) and received high ratings for greenness (Green Analytical Procedure Index, Analytical GREEnness) and practicality (Blue Applicability Grade Index).

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Solid Phase ExtractionWastewaterWater Pollutants, ChemicalCosmeticsWastewater-Based Epidemiological MonitoringTandem Mass SpectrometryPharmaceutical PreparationsChromatography, LiquidAutomationHumansGreen Chemistry TechnologyChromatography, High Pressure LiquidLiquid Chromatography-Mass Spectrometry

Stichwörter der Autor:innen

LC-MS/MSMAX SPE cartridgesPharmaceuticals and Personal Care Products (PPCPs)automated extractiongreenness assessmentmethod validationwastewater

Substanzen

WastewaterWater Pollutants, ChemicalCosmeticsPharmaceutical Preparations

Autor:innen und Institutionen

  • RASID Laboratory of Abu Dhabi Quality & Conformity Council (ADQCC) & M42 Environmental Sciences, Abu Dhabi P.O. Box 853, United Arab Emirates.
  • Abu Dhabi Quality and Conformity Council UAE, Abu Dhabi P.O. Box 853, United Arab Emirates.

ORCID-Profile: Bhaskar Karubothula, Dnyaneshwar Shinde, Raghu Tadala, Wael Faroug Elamin

Zitieren

APA

Karubothula, B., Kota, V. V., Shinde, D., Tadala, R., Cheerala, V., Salem, S. B., Elamin, W. F., & Brudecki, G. (2025). Next-Generation Wastewater-Based Epidemiology: Green Automation for Detecting 69 Multiclass Pharmaceutical and Personal Care Products in Wastewater Using 96-Well Plate Solid-Phase Extraction by LC-MS/MS. Molecules. https://doi.org/10.3390/molecules30183694

Vancouver

Karubothula B, Kota VV, Shinde D, Tadala R, Cheerala V, Salem SB, et al. Next-Generation Wastewater-Based Epidemiology: Green Automation for Detecting 69 Multiclass Pharmaceutical and Personal Care Products in Wastewater Using 96-Well Plate Solid-Phase Extraction by LC-MS/MS. Molecules. 2025. doi:10.3390/molecules30183694

BibTeX
@article{Karubothula2025,
  author = {Karubothula, Bhaskar and Kota, Veera Venkataramana and Shinde, Dnyaneshwar and Tadala, Raghu and Cheerala, Vishnu and Salem, Samara Bin and Elamin, Wael Faroug and Brudecki, Grzegorz},
  title = {Next-Generation Wastewater-Based Epidemiology: Green Automation for Detecting 69 Multiclass Pharmaceutical and Personal Care Products in Wastewater Using 96-Well Plate Solid-Phase Extraction by LC-MS/MS},
  journal = {Molecules},
  year = {2025},
  doi = {10.3390/molecules30183694}
}
Kostenlos starten →