EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Intraoperative Ocular Blood Flow Dynamics in Response to Intraocular Pressure Fluctuations During Vitrectomy for Proliferative Diabetic Retinopathy

Ryuya Hashimoto, Naoki Fujioka, Kazufumi Tanaka, Serika Moriyama, Takatoshi Maeno

Journal of Clinical Medicine · 09.03.2026 · 15 (5) · 2080

DOI: 10.3390/jcm15052080 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Medicine, online erschienen am 09.03.2026. Verfasst von Ryuya Hashimoto und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Toho University Sakura Medical Center, 564-1 Shimoshizu, Sakura 285-8741, Japan. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/Objectives: This study aimed to evaluate the autoregulatory capacity of optic nerve head (ONH) tissue blood flow in response to intraocular pressure (IOP) fluctuations during vitrectomy in patients with proliferative diabetic retinopathy (PDR). We hypothesized that impaired autoregulation of ONH tissue blood flow in response to intraoperative IOP fluctuations could contribute to subsequent ONH atrophy and the development of visual field defects in PDR patients following vitrectomy.

Methods

We included five eyes from five patients with PDR (mean age 70.6 ± 9.0 years) undergoing 25-gauge pars plana vitrectomy. ONH tissue blood flow was quantitatively assessed using intraoperative laser speckle flowgraphy. Mean blur rate in the tissue area (MT), an indicator of ONH tissue blood flow, was measured at baseline (infusion pressure 0 mmHg), during sustained elevation to 25 mmHg (at 5 and 10 min), and 1 min after return to baseline (11 min). IOP was modulated using the IOP Control system of the Constellation platform.

Results

Elevation of IOP to 25 mmHg significantly reduced ONH tissue blood flow, with MT decreasing by 29% at 10 min compared with baseline (p < 0.05, Dunn’s multiple comparisons test). After IOP returned to baseline, MT significantly recovered compared with the 10 min measurement (p < 0.05) and returned to levels not significantly different from baseline (p > 0.05).

Conclusions

MT decreases during intraoperative IOP elevation in PDR undergoing vitrectomy, but recovers after the return to baseline pressure, suggesting preserved short-term autoregulatory capacity. Careful IOP management during vitrectomy remains important in eyes with PDR.

Schlagwörter

Stichwörter der Autor:innen

autoregulationblood flowlaser speckle flowgraphyoptic nerve headproliferative diabetic retinopathyvitrectomy

Autor:innen und Institutionen

  • Department of Ophthalmology, Toho University Sakura Medical Center, 564-1 Shimoshizu, Sakura 285-8741, Japan.

Zitieren

APA

Hashimoto, R., Fujioka, N., Tanaka, K., Moriyama, S., & Maeno, T. (2026). Intraoperative Ocular Blood Flow Dynamics in Response to Intraocular Pressure Fluctuations During Vitrectomy for Proliferative Diabetic Retinopathy. Journal of Clinical Medicine, 15(5), 2080. https://doi.org/10.3390/jcm15052080

Vancouver

Hashimoto R, Fujioka N, Tanaka K, Moriyama S, Maeno T. Intraoperative Ocular Blood Flow Dynamics in Response to Intraocular Pressure Fluctuations During Vitrectomy for Proliferative Diabetic Retinopathy. Journal of Clinical Medicine. 2026;15(5):2080. doi:10.3390/jcm15052080

BibTeX
@article{Hashimoto2026,
  author = {Hashimoto, Ryuya and Fujioka, Naoki and Tanaka, Kazufumi and Moriyama, Serika and Maeno, Takatoshi},
  title = {Intraoperative Ocular Blood Flow Dynamics in Response to Intraocular Pressure Fluctuations During Vitrectomy for Proliferative Diabetic Retinopathy},
  journal = {Journal of Clinical Medicine},
  year = {2026},
  volume = {15},
  number = {5},
  pages = {2080},
  doi = {10.3390/jcm15052080}
}
Kostenlos starten →