Fire Development and Spread in a Two-Room Wooden Site Cabin: Full-Scale Experiment and FDS Validation
Fire · 06.11.2026 · 9 (11) · 494
DOI: 10.3390/fire9110494 ↗Kurz gefasst
Fachartikel in der Zeitschrift Fire, online erschienen am 06.11.2026. Verfasst von Sanjay K. Khattri und 3 weiteren Autor:innen. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Wooden site cabins and modular units are combustible enclosures in which a single furniture fire can rapidly involve adjacent rooms, yet full-scale experimental data on multi-compartment fire development involving combustible interior linings remain scarce. This paper presents a full-scale fire experiment in a two-room wooden site cabin with combustible linings, supported by a simplified numerical investigation using the Fire Dynamics Simulator (FDS). An F21-type armchair, ignited using heptane as an accelerant in the corner of the fire room, served as the primary fire source. Temperature development was monitored using 19 thermocouples distributed across the compartments, doorways, and window. During the experiment, the fire developed rapidly from the armchair, reaching flashover in the primary room after approximately 2.5 min before spreading through the internal doorway into the adjacent compartment and subsequently causing window failure. The FDS model employed a simplified combustible-lining representation, with surface ignition at 340 °C and a prescribed heat release rate per unit area (HRRPUA) of 150 kW m−2. Following an empirically determined temporal alignment of 46 s, the simulation reproduced the general temperature development during the growth phase and early fully developed stage. The interval between the earliest flashover threshold crossings in the two rooms was 36 s experimentally and 24 s in the simulation, indicating a more rapid transition between compartments in the model. This difference may partly reflect the simplified treatment of combustible surface ignition and fire spread. However, the temporal alignment and simplified modelling assumptions limit conclusions regarding independent predictive accuracy, particularly for event timing and later-stage temperature development. The primary contribution is a full-scale experimental reference case for investigating fire development and spread in lightweight, combustible multi-compartment structures. The experimental data and supporting numerical materials are openly available through Zenodo, facilitating further model assessment and research.
Zitieren
APA
Khattri, S. K., Strand, R. D., Meyer, A. K., & Kraaijeveld, A. (2026). Fire Development and Spread in a Two-Room Wooden Site Cabin: Full-Scale Experiment and FDS Validation. Fire, 9(11), 494. https://doi.org/10.3390/fire9110494
Vancouver
Khattri SK, Strand RD, Meyer AK, Kraaijeveld A. Fire Development and Spread in a Two-Room Wooden Site Cabin: Full-Scale Experiment and FDS Validation. Fire. 2026;9(11):494. doi:10.3390/fire9110494
BibTeX
@article{Khattri2026,
author = {Khattri, Sanjay K. and Strand, Ruben D. and Meyer, Anita K. and Kraaijeveld, Arjen},
title = {Fire Development and Spread in a Two-Room Wooden Site Cabin: Full-Scale Experiment and FDS Validation},
journal = {Fire},
year = {2026},
volume = {9},
number = {11},
pages = {494},
doi = {10.3390/fire9110494}
}