A Source-Traced PET/CT Scanner Performance Database (2004–2024): The Sphere-Size Dependence of Time-of-Flight Contrast Recovery

Rajeh Assiri, Ibrahim Hadadi, Mohammed Asiri, Abdulaziz Yahya M. Hussain, Hussein Alshaari, Mohammad Sayed, Mansour M. Alqahtani

Diagnostics · 2026-11-11 · 16 (22) · 3725

DOI: 10.3390/diagnostics16223725 ↗
AbstractBibliografische Angaben

Abstract

Background: Small-lesion quantification is a key task in diagnostic PET/CT. However, published performance data span two decades and multiple NEMA NU 2 revisions, complicating comparisons. We developed a source-traced database to examine how reconstruction-associated improvements in hot-sphere contrast recovery vary with sphere diameter, providing reference data for phantom-based protocol optimisation. Methods: Published NEMA and phantom measurements were source-verified, linked to scanner geometry, and annotated with acquisition and reconstruction conditions. Contrast recovery at a 4:1 sphere-to-background activity ratio (151 measurements; 13 scanners) was analysed using mixed-effects meta-regression with a scanner random intercept. Results: The database included 28 scanner models (2004–2024), 610 measurements and 43 publications. Descriptively, sensitivity was 3.8–10.9 cps/kBq for lutetium-based analogue scanners, 12.1–47.6 for conventional-geometry digital scanners and 176–192 for total-body scanners. Time of flight (TOF) was associated with a 7.9-percentage-point-higher contrast recovery (95% CI 4.8 to 11.1), but the association varied with sphere diameter (p < 0.001) and was significant only at 10–17 mm (11.4, 9.9 and 7.0 points); estimates at 28 and 37 mm rested on four to five scanners and were imprecise. The median between-laboratory difference under matched conditions was 5.7 points. Point-spread-function and regularised-reconstruction effects were not robust. Conclusions: In phantom measurements, TOF-associated gains were concentrated at 10–17 mm. These data provide reference values for phantom-based protocol optimisation, harmonisation and acceptance testing; they do not measure lesion detectability or diagnostic accuracy, which require patient-based validation.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →