Microfluidic Chamber Design for Organ-on-a-Chip: A Computational Fluid Dynamics Study of Pillar Geometry and Pulsatile Perfusion

Andi Liao iD, Jiwen Xiong, Zhirong Tong, Lin Zhou, Jinlong Liu

Biosensors · 08.01.2026 · 16 (1) · 49

DOI: 10.3390/bios16010049 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, online erschienen am 08.01.2026. Verfasst von Andi Liao und 4 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Pediatric Translational Medicine, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai 200127,…. Hauptthemen laut MEDLINE: Hydrodynamics, Lab-On-A-Chip Devices, Microfluidics, Microfluidic Analytical Techniques. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: the National Nature Science Foundation of China, the Fundamental Research Funds for the Central Universities, the fund of Science and Technology Commission of Shanghai Municipality.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Organ-on-a-Chip (OOC) platforms are microfluidic systems that recreate key features of human organ physiology in vitro via controlled perfusion. Fluid mechanical stimuli strongly influence cell morphology and function, making this important for cardiovascular OOC applications exposed to pulsatile blood flow. However, many existing OOC devices employ relatively simple chamber geometries and steady inflow assumptions, which may cause non-uniform shear exposure to cells, create stagnant regions with prolonged residence time, and overlook the specific effects of pulsatile perfusion. Here, we used computational fluid dynamics (CFD) to investigate how chamber geometry and inflow conditions shape the near-wall flow environment on a cell culture surface at a matched cycle-averaged volumetric flow rate. Numerical results demonstrated that pillarized chambers markedly reduced relative residence time (RRT) versus the flat chamber, and the small pillar configuration produced the most uniform time-averaged wall shear stress (TAWSS) distribution among the tested designs. Phase-resolved analysis further showed that wall shear stress varies with waveform phase, indicating that steady inflow may not capture features of pulsatile perfusion. These findings provide practical guidance for pillar geometries and perfusion conditions to create more controlled and physiologically relevant microenvironments in OOC platforms, thus improving the reliability of cell experimental readouts.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HydrodynamicsLab-On-A-Chip DevicesMicrofluidicsMicrofluidic Analytical TechniquesHumansPulsatile FlowPerfusionMicrophysiological SystemsEquipment Design

Stichwörter der Autor:innen

computational fluid dynamicsmicrofluidic chamberorgan-on-a-chippillar geometrypulsatile flow

Autor:innen und Institutionen

  • Institute of Pediatric Translational Medicine, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai 200127, China.
  • Department of Cardiothoracic Surgery, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai 200127, China.
  • Shanghai Engineering Research Center of Virtual Reality of Structural Heart Disease, Shanghai Children's Medical Center, Shanghai Jiao Tong University School of Medicine, Shanghai 200127, China.
  • State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai 200050, China.

ORCID-Profile: Andi Liao

Förderung

  • the National Nature Science Foundation of China
  • the Fundamental Research Funds for the Central Universities
  • the fund of Science and Technology Commission of Shanghai Municipality
  • National Nature Science Foundation of China
  • Fundamental Research Funds for the Central Universities
  • fund of Science and Technology Commission of Shanghai Municipality

Zitieren

APA

Liao, A., Xiong, J., Tong, Z., Zhou, L., & Liu, J. (2026). Microfluidic Chamber Design for Organ-on-a-Chip: A Computational Fluid Dynamics Study of Pillar Geometry and Pulsatile Perfusion. Biosensors, 16(1), 49. https://doi.org/10.3390/bios16010049

Vancouver

Liao A, Xiong J, Tong Z, Zhou L, Liu J. Microfluidic Chamber Design for Organ-on-a-Chip: A Computational Fluid Dynamics Study of Pillar Geometry and Pulsatile Perfusion. Biosensors. 2026;16(1):49. doi:10.3390/bios16010049

BibTeX
@article{Liao2026,
  author = {Liao, Andi and Xiong, Jiwen and Tong, Zhirong and Zhou, Lin and Liu, Jinlong},
  title = {Microfluidic Chamber Design for Organ-on-a-Chip: A Computational Fluid Dynamics Study of Pillar Geometry and Pulsatile Perfusion},
  journal = {Biosensors},
  year = {2026},
  volume = {16},
  number = {1},
  pages = {49},
  doi = {10.3390/bios16010049}
}
Kostenlos starten →