EUVIMEDEUVIMED entdecken
CrossrefInfokarte

Cross-subject EEG emotion recognition network based on moment channel attention

Shuran Yang, Mushan Han

Frontiers in Psychiatry · 2026-11-11 · 17

DOI: 10.3389/fpsyt.2026.1992929 ↗
AbstractBibliografische Angaben

Abstract

While most cross-subject EEG emotion recognition studies focus on average accuracy, the high inter-subject variability of EEG signals causes severe performance inconsistency across individuals. This inconsistency poses a critical barrier to real-world deployment but has received insufficient attention. To address this issue, this study proposes a hybrid emotion recognition model integrating moment channel attention and Transformer, termed the Moment Attention Convolution–Emotion Transformer Network (MAC-ETN). The proposed hybrid network consists of three components: a local temporal feature extractor, a Moment Channel Attention Network (MCA), and a global temporal feature extractor. Specifically, depthwise and separable convolutions are employed to extract local temporal features. The moment channel attention mechanism incorporates the first-order moment (mean), second-order moment (variance), and third-order moment (skewness) for channel importance calibration; and global dependency modeling is achieved through a Transformer encoder. Performance evaluation is conducted on two public datasets, DEAP and MAHNOB-HCI, using leave-one-subject-out cross-validation (LOSO-CV). The experimental results show that the main advantage of MAC-ETN lies in markedly reduced cross-subject performance variability rather than higher mean accuracy. On the DEAP dataset, the mean accuracy of MAC-ETN (61.26% for arousal and 60.47% for valence is lower than that of the strongest baselines reported under the same LOSO protocol, while its accuracy standard deviation (7.88% and 5.31%) is the lowest among all compared methods. On the MAHNOB-HCI dataset, the F1 standard deviation of MAC-ETN is 1.48% for arousal and 0.30% for valence, far below the values reported for the baselines in the literature, although the latter were obtained under a subject-dependent protocol and with a different F1 definition, so this comparison is indicative only. These results indicate that MAC-ETN reduces cross-subject performance variability at a moderate level of accuracy, which is relevant for practical EEG-based emotion recognition applications.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →