EUVIMEDEUVIMED entdecken
CrossrefInfokarte

Thermoforming time variability in clear aligner fabrication: A pilot in vitro study

Thi Bich Van Tran, Ngoc Anh Thu Pham

APOS Trends in Orthodontics · 2026-08-04 · 16 · 260-266

DOI: 10.25259/apos_36_2026 ↗
AbstractBibliografische Angaben

Abstract

Objectives: Thermoforming time is a key process parameter in the fabrication of clear orthodontic aligners. Manufacturer-recommended heating durations, however, may not reflect changes in heating time during consecutive thermoforming cycles. This study investigated variations in thermoforming time across repeated forming cycles to support optimization of in-house clear aligner fabrication protocols. Material and Methods: In this in vitro study, 100 Zendura FLX thermoplastic sheets (0.76 mm) were thermoformed in five independent sessions, each comprising 20 consecutive cycles, using a Drufomat Scan pressure-forming unit initiated from a cold-start condition. Heating was manually terminated at a standardized sheet deflection of 16 mm, based on preliminary pilot testing, monitored using a parallel laser guidance system. Heating duration was recorded for each cycle. Data were analyzed using a linear mixed-effects model with Bonferroni-adjusted post hoc comparisons. Thermal stabilization was defined as the earliest cycle at which no significant difference in heating time was observed between consecutive cycles ( p > 0.05). Linear regression analysis was applied to characterize heating-time reduction before stabilization. Results: Heating duration ranged from 60.2 to 111.6 s across all cycles. Heating time decreased markedly during the first five cycles and stabilized from the sixth cycle onward ( p > 0.05). During the steady-state phase, the mean heating time was 64.41 ± 3.06 s, remaining significantly longer than the manufacturer-recommended value of 50 s ( p < 0.0001). Linear regression showed a significant reduction in heating time during the pre-stabilization phase (8.56 s/cycle; R 2 = 0.77). Conclusion: Thermoforming time decreased during early fabrication cycles due to cumulative heat retention within the thermoforming unit. Even after thermal stabilization, heating durations exceeded manufacturer-recommended values. These findings indicate that preset heating times should be regarded as reference values and experimentally adjusted according to material and machine-specific behavior.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →