Ultrasound Imaging of Lumbar Multifidus Morphology and Quality – A Prospective Study on Monitoring Acute Adaptations to Specific Exercise and on Reliability
JOSPT Open · 2024-10 · 2 (4) · 354-363
DOI: 10.2519/josptopen.2024.0253 ↗Abstract
OBJECTIVE: To test the reliability of a rehabilitative ultrasound imaging (RUSI) protocol for analyzing lumbar multifidus morphologic characteristics for use by clinicians, and to analyze the specificity of isolated lumbar extension resistance exercise (ILEX) DESIGN: Intrarater reliability and interrater (imaging and quantification) reliability. METHODS: A standardized RUSI protocol was developed and the reliability of the procedure and image analysis (intraclass correlations coefficient [ICC], standard error of the measurement [SEM], minimum detectable change [MDC%]) was analyzed. Lumbar multifidus RUSI measures of muscles thickness, cross-sectional area, and echogenicity were obtained before and after 1 ILEX set with uniform time under tension and range of motion (12°-42°). RESULTS: Intrarater (between-day) reliability was similar (ICC, 0.88-0.97; SEM, 0.14-5.08; MDC%: 11-20) compared to interrater (same day) imaging reliability (ICC, 0.91-0.99; SEM, 0.09-3.78; MDC%, 8-15) and interrater quantification reliability (ICC, 0.83-0.97; SEM, 0.07-2.80; MDC%: 6-25). There was a significant increase of lumbar multifidus muscle thickness (pre-ILEX, 2.94 cm; post-ILEX, 3.16 cm; P