EUVIMEDEUVIMED entdecken
CrossrefInfokarte

Fixation of proximal humeral Salter-Harris type 1 fractures in a 3-dimensionally printed skeletally immature canine bone model: a biomechanical assessment of fully threaded headless cannulated screws

Tae-Woong Hwang, Eunseo Kang, Jung-Moon Kim, Hwi-Yool Kim

American Journal of Veterinary Research · 2026-11-01 · 87 (11)

DOI: 10.2460/ajvr.26.05.0221 ↗
AbstractBibliografische Angaben

Abstract

Abstract Objective To compare the biomechanical stability of 4 fixation techniques for proximal humeral physeal fractures in skeletally immature canines using 3-D–printed models. Methods This experimental in vitro study was conducted from September 25, 2025, through April 22, 2026. To strictly control biological variability, identical 3-D–printed models of juvenile canine proximal humeral Salter-Harris type 1 fractures (CT-derived from a 6-month-old 26-kg Labrador Retriever) were evaluated across 4 groups: pin and tension band wire (group A), partially threaded cannulated screw (group B), fully threaded headless cannulated screw (FTHCS) alone (group C), and FTHCS with a 1.6-mm Kirschner (K)-wire (group D). Tensile loading was applied at 10 mm/min at 105° to simulate supraspinatus traction. Outcomes included loads at 1- and 2-mm displacements, maximum failure load, and failure modes. Results Twenty-four models were tested (n = 6/group). Group D exhibited significantly higher resistance at 1-mm (663.95 N) and 2-mm (1,080.33 N) displacements than other groups. At 1-mm displacement, group D outperformed groups C, A, and B (mean differences [MD]: 206.2 N, 380.6 N, and 405.7 N, respectively; P < .0083). Maximum failure load did not differ significantly. Group B failed via localized proximal crushing and subsidence, whereas FTHCS groups (C, D) preserved proximal integrity, failing distally. Conclusions In this 3-D–printed model, FTHCS combined with a K-wire provided superior resistance to tensile displacement compared with other tested constructs. Clinical Relevance FTHCS augmented with a K-wire may offer a biomechanically robust alternative mitigating subhead bone collapse, providing sufficient standalone stability for early rehabilitation in immature canines.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →