Photocuring Proficiency: Effects of Experience, Power Setting, and Preparation Type on Radiant Exposure

M Lawrence, L Formica, C Carrico, TA Imbery

Operative Dentistry · 2026-09 · 51 (5) · 455-464

DOI: 10.2341/26-065-l ↗
AbstractBibliografische Angaben

Abstract

ABSTRACT Purpose: Adequate polymerization of resin composite is dependent upon many variables, three of which are operator skill, power settings, and preparation type. The purpose of this study was to evaluate the effects of student experience, power settings, and preparation type on the delivery of radiant exposure to simulated preparations. Methods: Thirty-one third-year and thirty-one fourth-year predoctoral dental students participated in this laboratory study. Using Managing Accurate Resin Curing - Patient Simulator, MARC-PS (BlueLight Analytic, Halifax, Nova Scotia, Canada), participants photocured simulated Class I and Class III preparations using a Valo Grand (Ultradent, South Jordan UT) light-curing unit using three power settings: Standard, High-Power Plus, and Xtra. The goal was to obtain 16 J/cm 2 of radiant exposure. Total radiant exposure and the time required to obtain the minimum radiant exposure were recorded. Data were analyzed using a three-way ANOVA with Tukey-adjusted post hoc comparisons at a confidence level of 95%. Results: All three independent variables (student experience, preparation type, and power setting) significantly influenced both radiant exposure and curing time. Fourth-year students achieved higher radiant exposure (mean difference = 1.63 J/cm 2 , p = 0.018) and required less curing time (mean difference = 1.1 seconds, p = 0.018) than third-year students. Class III preparations received higher radiant exposure (mean difference = 5.4 J/cm 2 , p < 0.0001) and required less time (mean difference = 2.9 seconds, p < 0.0001) than Class I preparations. High-Power Plus resulted in significantly greater radiant exposure and shorter cure times than both Standard and Xtra power settings. Conclusions: Operator experience and preparation type significantly influenced radiant exposure. Xtra power mode did not offer any advantage over High Power Plus. The MARC-PS demonstrates the importance of proper photocuring techniques to novice clinicians.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →