Effect of Post-Setting Time on the Bond Strength of Bioceramic Repair Cements to Resin Composite
Operative Dentistry · 2026-09 · 51 (5) · 413-425
DOI: 10.2341/25-139-l ↗Abstract
ABSTRACT Objective: Bioceramic repair cements (BRCs) are widely used in reparative and endodontic procedures; however, the optimal timing for adhesive restoration over these materials remains unclear, particularly regarding the stability of the adhesive interface over time. The aim of this study was to investigate the optimal timing for restoring BRCs by evaluating microshear bond strength (μSBS) immediately, seven days, and 35 days after initial setting; mode of failure; and adhesive interface. Methods: A total of 216 BRC specimens were fabricated and divided into four groups (n = 54): G1) Biodentine (Septodont); G2) CIMMO HD (CIMMO – Biocerâmicos); G3) MTA Repair HP (Angelus); and G4) BIO-C Repair (Angelus). Each group was subdivided into three subgroups (n = 18), corresponding to the time of restoration. A two-step self-etch adhesive system (Clearfil SE Bond, Kuraray Noritake) was applied to all specimens. A silicone mold with an orifice of 0.9 mm in diameter and 0.5 mm high was fabricated and positioned over the BRC. The orifice was filled with a flowable composite, and μSBS testing was performed after 24 hours. Failure modes were classified under an optical microscope at 40× magnification. The hybrid layer was analyzed by scanning electron microscope (SEM). Data were assessed for normality (Shapiro-Wilk test), confirming a normal distribution. Repeated-measures ANOVA was applied, followed by the Tukey post hoc test (α = 0.05). Results: Statistically significant differences in μSBS were observed for post-setting times and cement types ( p < 0.001). The immediate setting data showed the μSBS for Biodentine to be significantly higher than all of the remaining cements ( p < 0.05). At seven days, BIO-C Repair showed significantly lower μSBS than Biodentine ( p = 0.01) and MTA Repair HP ( p < 0.01), but did not differ significantly from CIMMO HD ( p = 0.78). After 35 days, Biodentine and CIMMO HD showed similar μSBS values ( p = 0.97), and both exhibited significantly greater values than MTA Repair HP ( p < 0.01) and BIO-C Repair ( p < 0.01). An increase in μSBS was observed for all cements at seven days compared with immediate measurements ( p < 0.05). From seven to 35 days, μSBS decreased for MTA Repair HP ( p < 0.001), but remained unchanged for Biodentine ( p = 1.00), CIMMO HD ( p = 1.00), and BIO-C Repair ( p = 0.61). A statistically significant association between failure type and material type was found only at 35 days ( p = 0.004). Cohesive failure within the BRCs was the predominant failure mode. Conclusion: The results demonstrate that the μSBS between the BRC and the restorative material is dependent on both the biomaterial type and time. Biodentine exhibited the highest immediate bond strength and long-term stability, with significant differences depending on the cement used for comparison.
EUVIMED