A Benchmarking Framework for Real-Time 3D Pose Estimation in Motor Rehabilitation: Development and Proof-of-Concept Study

Emanuel Alexander Lorenz, Beatrix Vereijken, Kerstin Bach, Xiaomeng Su

JMIR Rehabilitation and Assistive Technologies · 2026-11-09 · 13 · e91360-e91360

DOI: 10.2196/91360 ↗
AbstractBibliografische Angaben

Abstract

Abstract Background Accurate motor assessment is crucial for diagnosing and monitoring neurological and musculoskeletal disorders. However, traditional manual and semiautomated methods can be subjective, time-consuming, or expensive. Real-time 3D human pose estimation (HPE) is emerging as a low-cost, noninvasive alternative. However, its clinical adoption is limited due to a lack of thorough, standardized evaluation of its accuracy and robustness in real-world clinical settings. Objective This study aims to introduce a technical pipeline for evaluating the applicability of real-time 3D HPE in simulated clinical rehabilitation settings. Methods The framework facilitates the evaluation of an HPE model’s spatial and spatiotemporal accuracy, real-time capability, and robustness against simulated common setup errors and camera position variations, using a marker-based motion capture system as a gold-standard baseline. To address the technical challenge of interdataset comparison, the framework includes a morphing model that harmonizes differing joint definitions. Results Applying the framework to a popular, accessible real-time algorithm (MediaPipe) on 4 healthy participants (N=127,828 frames) showed that simulated underexposure and defocus blur had negligible effects (rank-biserial correlation [RBC] ≤0.02), whereas body segment occlusion (mean-per-joint angular error [MPJAE] increase of 1.5, SD 10 degrees; +24.3%) and insufficient multiocular calibration (MPJAE increase of 7.8, SD 14 degrees; +123.4%, RBC=0.95) significantly degraded tracking accuracy. The framework also showed significant sensitivity to nonfrontal camera placements, both side- and back-facing views (RBC 0.41‐0.49 and bias up to 2.2 degrees/37.1%), relative to stable frontal placements (RBC ≤0.03). The skeleton morphing module reduced Procrustes-aligned mean per joint position error (PA-MPJPE) by 55.29 mm (N=79,423 frames, 57.2% reduction) and its SD by 24.69 mm (N=79,423 frames, 50.7%). Conclusions This study establishes a technical foundation for the standardized evaluation of markerless tracking for clinical applications, like motor rehabilitation. The morphing model enables interdataset comparison, and the proposed framework facilitates domain-specific interpretation of HPE performance. While further validation on pathological populations is required, this work provides the necessary engineering foundation for future validation studies.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →