EUVIMEDEUVIMED entdecken
Video/AudioOpen Access

Measuring Bound Attention During Complex Liver Surgery Planning: Feasibility Study

Tim Schneider iD, Timur Cetin iD, Stefan Uppenkamp iD, Dirk Weyhe iD, Thomas Muender iD, Anke V Reinschluessel iD, Daniela Salzmann iD, Verena Uslar iD

JMIR Formative Research · 2025

DOI: 10.2196/62740 ↗

Kurz gefasst

Video/Audio in der Zeitschrift JMIR Formative Research, 2025. Verfasst von Tim Schneider und 7 weiteren Autor:innen. Beteiligte Einrichtung: University Hospital for Visceral Surgery, PIUS-Hospital, Department for Human Medicine, Faculty VI, University of Oldenburg, Oldenburg, Germany. Hauptthemen laut MEDLINE: Surgeons, Attention, Surgery, Computer-Assisted, Smart Glasses. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The integration of advanced technologies such as augmented reality (AR) and virtual reality (VR) into surgical procedures has garnered significant attention. However, the introduction of these innovations requires thorough evaluation in the context of human-machine interaction. Despite their potential benefits, new technologies can complicate surgical tasks and increase the cognitive load on surgeons, potentially offsetting their intended advantages. It is crucial to evaluate these technologies not only for their functional improvements but also for their impact on the surgeon’s workload in clinical settings. A surgical team today must increasingly navigate advanced technologies such as AR and VR, aiming to reduce surgical trauma and enhance patient safety. However, each innovation needs to be evaluated in terms of human-machine interaction. Even if an innovation appears to bring advancements to the field it is applied in, it may complicate the work and increase the surgeon’s workload rather than benefiting the surgeon.

Objective

This study aims to establish a method for objectively determining the additional workload generated using AR or VR glasses in a clinical context for the first time.

Methods

Electroencephalography (EEG) signals were recorded using a passive auditory oddball paradigm while 9 participants performed surgical planning for liver resection across 3 different conditions: (1) using AR glasses, (2) VR glasses, and (3) the conventional planning software on a computer.

Results

The electrophysiological results, that is, the potentials evoked by the auditory stimulus, were compared with the subjectively perceived stress of the participants, as determined by the National Aeronautics and Space Administration-Task Load Index (NASA-TLX) questionnaire. The AR condition had the highest scores for mental demand (median 75, IQR 70-85), effort (median 55, IQR 30-65), and frustration (median 40, IQR 15-75) compared with the VR and PC conditions. The analysis of the EEG revealed a trend toward a lower amplitude of the N1 component as well as for the P3 component at the central electrodes in the AR condition, suggesting a higher workload for participants when using AR glasses. In addition, EEG components in the VR condition did not reveal any noticeable differences compared with the EEG components in the conventional planning condition. For the P1 component, the VR condition elicited significantly earlier latencies at the Fz electrode (mean 75.3 ms, SD 25.8 ms) compared with the PC condition (mean 99.4 ms, SD 28.6 ms).

Conclusions

The results suggest a lower stress level when using VR glasses compared with AR glasses, likely due to the 3D visualization of the liver model. Additionally, the alignment between subjectively determined results and objectively determined results confirms the validity of the study design applied in this research.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SurgeonsAttentionSurgery, Computer-AssistedSmart GlassesStress, PsychologicalPatient Care PlanningHepatectomyFeasibility StudiesHumansWorkloadUser-Computer InterfaceElectroencephalographyAugmented RealityVirtual RealityEvoked PotentialsAcoustic StimulationErgonomicsLiverMaleAdultImaging, Three-Dimensional

Stichwörter der Autor:innen

AEPAREEGERPNASA-TLXNational Aeronautics and Space Administration Task Load IndexVRauditory evoked potentialaugmented realityelectroencephalographyevent-related potentialoddball experimentsurgical planningvirtual realityworkload measurement

Autor:innen und Institutionen

  • University Hospital for Visceral Surgery, PIUS-Hospital, Department for Human Medicine, Faculty VI, University of Oldenburg, Oldenburg, Germany.
  • Department of Medical Physics and Acoustics, Faculty VI, University of Oldenburg, Oldenburg, Germany.
  • Digital Media Lab, Department of Mathematics and Computer Science, Faculty III, University of Bremen, Bremen, Germany.
  • Department of Computer and Information Science, University of Konstanz, Konstanz, Germany.

ORCID-Profile: Tim Schneider, Timur Cetin, Stefan Uppenkamp, Dirk Weyhe, Thomas Muender, Anke V Reinschluessel, Daniela Salzmann, Verena Uslar

Zitieren

APA

Schneider, T., Cetin, T., Uppenkamp, S., Weyhe, D., Muender, T., Reinschluessel, A. V., Salzmann, D., & Uslar, V. (2025). Measuring Bound Attention During Complex Liver Surgery Planning: Feasibility Study. JMIR Formative Research. https://doi.org/10.2196/62740

Vancouver

Schneider T, Cetin T, Uppenkamp S, Weyhe D, Muender T, Reinschluessel AV, et al. Measuring Bound Attention During Complex Liver Surgery Planning: Feasibility Study. JMIR Formative Research. 2025. doi:10.2196/62740

BibTeX
@article{Schneider2025,
  author = {Schneider, Tim and Cetin, Timur and Uppenkamp, Stefan and Weyhe, Dirk and Muender, Thomas and Reinschluessel, Anke V and Salzmann, Daniela and Uslar, Verena},
  title = {Measuring Bound Attention During Complex Liver Surgery Planning: Feasibility Study},
  journal = {JMIR Formative Research},
  year = {2025},
  doi = {10.2196/62740}
}
Kostenlos starten →