EUVIMEDEUVIMED entdecken
CrossrefInfokarte

Two-Stage Gamified Digital Assessment for Autism Spectrum Disorder Screening and the Limits of Differentiating Social Communication Disorder in Children and Adolescents: Cross-Sectional Diagnostic Accuracy Study Using Explainable Machine Learning

Minyoung Jung, Ju Ran, Ennyoung Lee, Youngkyung Sunwoo, SooYeon Kim, Ji-Hoon Kim, Sungja Cho

JMIR Serious Games · 2026-09-23 · 14 · e102714-e102714

DOI: 10.2196/102714 ↗
AbstractBibliografische Angaben

Abstract

Abstract Background Distinguishing autism spectrum disorder (ASD) from social communication disorder (SCD) is clinically challenging because both conditions present with overlapping social communication deficits. Standard caregiver-reported instruments capture surface-level behavioral similarities rather than underlying cognitive differences, motivating the development of digital gamified assessments that measure social cognitive processes directly. Objective This study developed and evaluated a 2-stage gamified digital pipeline: stage 1 (Buddy Plan, a self-report module) for high-sensitivity ASD screening, and stage 2 (Buddy Drill, story-based social-judgment scenarios), which was examined with a leakage-controlled analysis, for assessing whether ASD can be differentiated from SCD. Methods In this cross-sectional diagnostic accuracy study, 275 children and adolescents aged 6‐18 years (mean 11.07, SD 3.13 years; 175/275, 63.6% male) were recruited by convenience sampling from 5 clinical and community sites in the Republic of Korea (May 2024 to February 2025) across 5 Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5) groups: ASD (n=51), SCD (n=54), attention-deficit/hyperactivity disorder (n=23), high risk (n=52), and neurotypically developing (ND; n=95). Diagnoses were established by board-certified child psychiatrists. Participants completed 2 tablet-based modules: Buddy Plan (52 self-report items; stage 1) and Buddy Drill (153 story-based scenarios; stage 2). The primary outcome was diagnostic accuracy (area under the receiver operating characteristic curve [AUC], sensitivity, and specificity). Four machine learning algorithms were trained with nested cross-validation (5×5 folds). For stage 2, item selection and imputation were performed within each training fold. Explainability used Shapley Additive Explanations (SHAP). Significance was set at α=.05 (2-sided) with bootstrap 95% CIs. Results Group differences were tested by 1-way ANOVA. For stage 1 (ASD vs ND; n=146), random forest achieved a nested AUC of 0.912 (95% CI 0.856‐0.953). At a threshold of 0.200, sensitivity was 96.1% (49/51; 95% CI 86.8%‐99.5%) and specificity was 58.9% (56/95; 95% CI 48.4%‐68.9%), with 2 false negatives. For stage 2 (ASD vs SCD; n=100), the fully nested pipeline yielded only chance-level discrimination: regularized logistic regression achieved a nested AUC of 0.62 (95% CI 0.51‐0.74), and no feature configuration (self-report: 0.55, objective: 0.62, combined: 0.63) exceeded chance. SHAP identified 5 cross-algorithm stage 1 biomarkers with significant ASD-versus-ND differences (all P

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →