EUVIMEDEUVIMED entdecken
CrossrefInfokarte

Validation of Single-Camera MediaPipe BlazePose for Knee Joint Angle Measurement Across Multiple Functional Tasks: Concurrent Validity, Interrater Reliability, and Exploratory Test–Retest Reliability Study

Xiaotian Yue, YiXuan Gu, Bo Yu

JMIR Rehabilitation and Assistive Technologies · 2026-11-03 · 13 · e102399-e102399

DOI: 10.2196/102399 ↗
AbstractBibliografische Angaben

Abstract

Abstract Background Single-camera markerless pose estimation may support accessible knee movement assessment, but performance can depend on task, joint angle, and detection quality, and evidence across complementary measurement properties remains limited. Objective This study aimed to evaluate agreement of MediaPipe BlazePose Heavy knee-flexion estimates with goniometer-set static target positions and with Kinovea 2D video annotation for dynamic tasks, to assess interrater agreement of the Kinovea annotations, and to explore repeated-session performance in a small retest subsample. Methods Squat, sit-to-stand, and bilateral single-leg stance tasks were performed by 15 healthy adults during standardized lateral-view smartphone recording. Static knee flexion was assessed at 4 goniometer-set targets (30°, 60°, 90°, and 120°). Native hip-knee-ankle included angles were converted to clinical knee flexion (0° at full extension). Agreement was assessed using the intraclass correlation coefficient (ICC), specifically ICC 2,1 , signed bias and 95% limits of agreement, mean absolute error (MAE), and root mean square error (RMSE). Primary intervals used participant-cluster bootstrapping, and limits of agreement accounted for repeated measurements. Dynamic primary estimates were conditional on BlazePose target-frame confidence ≥0.3; low-confidence observations were also reported as detection failures and included in an all-output stress test. Four participants returned after 21 days to 29 days (median 25 d) for exploratory repeated-session analyses. Results Dynamic measurement was available in 177 of 210 observations (84.3%); 33 of 210 observations (15.7%) failed the confidence criterion. Conditional task-specific ICCs were 0.773 (95% CI 0.564 to 0.875; n=71, 15 participants) for squat, 0.632 (95% CI 0.455 to 0.726; n=58, 12 participants) for sit-to-stand, and 0.136 (95% CI −0.078 to 0.482; n=48, 15 participants) for combined single-leg stance. Task-specific availability was present for 71 of 75 observations (95%), 58 of 75 observations (77%), and 48 of 60 observations (80%), respectively. Without the quality gate, squat ICC was 0.428, and RMSE was 25.43°. Static agreement with set targets resulted in an ICC of 0.874 (95% CI 0.770 to 0.953), with RMSE of 15.49° and angle-dependent signed error. Kinovea interrater ICC was 0.999 (95% CI 0.998 to 0.999) overall, which did not establish 3D accuracy. Repeated-session estimates with the 4 participants remained exploratory. Conclusions With dynamic measurement available in 177 of 210 observations (84.3%), agreement among retained outputs depended on task, flexion angle, and detection quality. The findings support further feasibility and screening-level evaluation under controlled acquisition with per-recording quality checks; they do not support replacement of clinical goniometry, precise longitudinal decision-making, absolute 3D kinematic accuracy, or generalization to clinical populations or other smartphones.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →