EUVIMEDEUVIMED entdecken
CrossrefInfokarte

Coexistence of AI Nurse and AI-Simulated Patient in Nursing Education Using a Bidirectional Fine-Tuning Pipeline: Development and Content Analysis Study

Takeshi Koike, Yukie Majima

JMIR Biomedical Engineering · 2026-11-06 · 11 · e100778-e100778

DOI: 10.2196/100778 ↗
AbstractBibliografische Angaben

Abstract

Abstract Background Simulated patient systems are essential in nursing education but face actor scarcity, instructor burden, cost, and disrupted continuity where in-person simulation cannot be sustained. Existing large language model (LLM)–based systems address these issues but treat the dialogic partner—the AI nurse—as a static prompt or unspecialized model, compromising data collection quality and pedagogical applicability. Objective We report (1) the construction of 2 specialized fine-tuned models, NURSE-ONE (AI nurse) and PATIENT-ONE (AI-simulated patient), via a 5-step bidirectional fine-tuning pipeline; (2) their evaluation using Berelson content analysis validated by independent human coders; (3) an exploratory third-party evaluation by nursing faculty; and (4) the design of a coexistence simulation ecosystem supporting 3 operating modes, including offline disaster preparedness applicability. Methods On a single consumer-grade graphics processing unit (NVIDIA RTX 4090; 24 GB video random access memory), the multimodal base model gemma4-E4B-it was fine-tuned via low-rank adaptation in five steps: (1) a 251-scenario base from 29 institutionally authored nursing care plans and 20 items from the 115th Japanese National Nursing Examination; (2) a provisional dialogue system (AutoGen v18, maxmsg=25) to collect training dialogues; (3) NURSE-ONE fine-tuning across 3 training volume conditions (245, 735, and 1225 cases); (4) 4-condition Berelson comparison; and (5) PATIENT-ONE fine-tuning on NURSE-ONE–generated dialogues with a 3-condition comparison. Interrater reliability was confirmed by 2 independent nursing experts (196 blinded utterances, κ=0.770) and corroborated by 2 LLM raters (κ=0.742). Ten nursing faculty evaluated 3 coexistence modes in a working web user interface (21-item rubric; item-level content validity index=1.00). Results Four-condition Berelson analysis ( χ 2 15 =42.0, P

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →