EUVIMEDEUVIMED entdecken
CrossrefInfokarte

Accuracy of dynamic three-dimensional magnetic resonance perfusion imaging for the detection of coronary artery disease in patients with reduced ejection fraction

Sabrina Oebel, Alexander Gotschy, Ingo Paetsch, Cosima Jahnke, Sven Plein, Rolf Gebker, Sandra Hamada, Michael Frick, Jochen von Spiczak, Malgorzata Polacin, Frank Enseleit, Nikolaus Marx, Thomas F. Lüscher, Frank Ruschitzka, Sebastian Kozerke, Hatem Alkadhi, Robert Manka

Imaging · 2021

DOI: 10.1556/1647.2020.00007 ↗
AbstractBibliografische Angaben

Abstract

Abstract Background To assess the accuracy of 3D cardiovascular magnetic resonance (CMR) perfusion imaging for the detection of coronary artery disease (CAD) against fractional flow reserve (FFR) and quantitative coronary angiography (QCA) in patients with reduced ejection fraction (EF). Methods Out of 447 patients who underwent 3D CMR perfusion imaging (at 1.5 and 3.0 T under adenosine stress and at rest) at 5 European centers, 86 cases with an EF ≤50% were identified (mean age 64 ± 11 yrs, 80% male). Significant CAD was defined as a FFR value 50%. 86 individuals matched for age, gender and major cardiovascular risk factors, were chosen as the control group. Results The prevalence of CAD defined by FFR (50%), P = 0.4). In relation to FFR, 3D perfusion imaging yielded a sensitivity of 84.5% (95% CI 76.0–90.4) and specificity of 77.3% (95% CI 66.7–85.3). The sensitivity of perfusion imaging was higher in patients with an EF≤50% (90.2 vs. 78.3%, P = 0.1) whereas specificity showed the reverse (62.9 vs. 90.0%, P = 0.005) The diagnostic accuracy was comparable in both subgroups (AUC 79.1 vs. 83.7%, P = 0.25). According to QCA, the prevalence of CAD was 78 vs. 72% ( P = 0.4). Perfusion imaging yielded a sensitivity and specificity of 82.1 vs. 62.9%, P = 0.01 and 79.0 vs. 95.8%, P = 0.09 respectively with a high diagnostic accuracy in both subgroups (AUC 82.0 vs. 80.5%). Conclusion 3D-CMR perfusion imaging yields a high sensitivity and diagnostic accuracy with regards to the detection of significant CAD irrespective of left ventricular (LV) systolic function.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →