Correlations between three-dimensional speckle-tracking echocardiography-derived left atrial functional parameters and aortic stiffness in healthy subjects – Results from the MAGYAR-Healthy Study
Acta Physiologica Hungarica · 2015
DOI: 10.1556/036.102.2015.2.10 ↗Abstract
Left atrial (LA) distension has been demonstrated to be linked with aortic stiffness in different patient populations. Three-dimensional (3D) speckle-tracking echocardiography (STE) seems to be a promising tool for volumetric and functional evaluation of the LA. The aim of the present study was to determine whether correlations exist between 3DSTE-derived LA volume-based and strain parameters characterizing all phasic functions of the LA and echocardiographic aortic elastic properties in healthy subjects. The study included 19 healthy volunteers (mean age: 37.9 ± 11.4 years, 11 men) who had undergone complete two-dimensional (2D) Doppler transthoracic echocardiography extended with the assessment of aortic elastic properties and 3DSTE. Results : None of LA volumes correlated with echocardiographic aortic elastic properties. Active atrial stroke volume correlated with aortic stiffness index (ASI, r = 0.45, p = 0.05). None of other volume-based functional properties signifcantly correlated with aortic stiffness parameters. Global peak 3D strain correlated with aortic strain ( r = ‒0.46, p = 0.05). global radial pre-atrial contraction strain correlated with ASI ( r = ‒0.49, p = 0.04) and AS ( r = ‒0.50, p = 0.04). Conclusions: Correlations exist between 3DSTE-derived LA functional parameters and eschocardiographic aortic elastic properties in healthy subjects.