Validation of nocturnal resting heart rate and heart rate variability in consumer wearables
Physiological Reports · 2025-08 · 13 (16)
DOI: 10.14814/phy2.70527 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Physiological Reports, online erschienen am 20.08.2025. Verfasst von Michael B Dial und 5 weiteren Autor:innen. Beteiligte Einrichtung: Human Performance Collaborative, Office of Research, The Ohio State University, Columbus, Ohio, USA. Hauptthemen laut MEDLINE: Heart Rate, Wearable Electronic Devices, Sleep. Die Arbeit wurde bisher 32-mal zitiert (Crossref) und nennt 78 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: DOD | USAF | AMC | Air Force Research Laboratory (AFRL), Air Force Research Laboratory.
Abstract (Originalsprache)
Modern wearable devices report several heart rate‐based nocturnal health metrics, including resting heart rate (RHR) and heart rate variability (HRV). The purpose of this study was to assess the validity of nocturnal RHR and HRV from five wearable devices (Garmin Fenix 6, Oura Generation 3, Oura Generation 4, Polar Grit X Pro, & Whoop 4.0) against an electrocardiogram (ECG) reference. Thirteen healthy adults (6 females) wore an ECG reference and multiple wearables simultaneously during sleep, totaling 536 nights. Interdevice accuracy varied significantly ( p < 0.05). For RHR, Oura Gen 3 (Lin's Concordance [CCC] = 0.97, mean absolute percentage error [MAPE] = 1.67 ± 1.54%) and Gen 4 (CCC = 0.98, MAPE = 1.94 ± 2.51%) demonstrated the highest accuracy, outperforming Polar's poor (CCC = 0.86, MAPE = 2.71 ± 2.75%) and WHOOP's moderate agreement (CCC = 0.91, MAPE = 3.00 ± 2.15%). Garmin was excluded from RHR analyses due to methodological inconsistencies. For HRV, Oura devices provided the highest accuracy; Oura Gen 4 (CCC = 0.99, MAPE = 5.96 ± 5.12%), Oura Gen 3 (CCC = 0.97, MAPE = 7.15 ± 5.48%). WHOOP showed moderate accuracy (CCC = 0.94, MAPE = 8.17 ± 10.49%), followed by poor agreement from both Garmin (CCC = 0.87, MAPE = 10.52 ± 8.63%) and Polar (CCC = 0.82, MAPE = 16.32 ± 24.39%). Oura devices showed the highest agreement for RHR and HRV, and WHOOP showed acceptable agreement, whereas Garmin Fenix and Polar demonstrated lower concordance, highlighting the importance of continuous validation and providing valuable benchmarks for clinicians, researchers, and consumers.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Human Performance Collaborative, Office of Research, The Ohio State University, Columbus, Ohio, USA.
- STRONG Lab, 711th Human Performance Wing, Air Force Research Laboratory, Wright-Patterson Air Force Base, Dayton, Ohio, USA.
ORCID-Profile: Michael B Dial
Förderung
- DOD | USAF | AMC | Air Force Research Laboratory (AFRL)
- Air Force Research Laboratory
Zitieren
APA
Dial, M. B., Hollander, M. E., Vatne, E. A., Emerson, A. M., Edwards, N. A., & Hagen, J. A. (2025). Validation of nocturnal resting heart rate and heart rate variability in consumer wearables. Physiological Reports, 13(16). https://doi.org/10.14814/phy2.70527
Vancouver
Dial MB, Hollander ME, Vatne EA, Emerson AM, Edwards NA, Hagen JA. Validation of nocturnal resting heart rate and heart rate variability in consumer wearables. Physiological Reports. 2025;13(16). doi:10.14814/phy2.70527
BibTeX
@article{Dial2025,
author = {Dial, Michael B and Hollander, Margaret E and Vatne, Emaly A and Emerson, Angela M and Edwards, Nathan A and Hagen, Joshua A},
title = {Validation of nocturnal resting heart rate and heart rate variability in consumer wearables},
journal = {Physiological Reports},
year = {2025},
volume = {13},
number = {16},
doi = {10.14814/phy2.70527}
}
EUVIMED