EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Untangling discrepancies between cerebrovascular autoregulation correlation coefficients: An exploration of filters, coherence and power

Stefan Yu Bögli iD, Ihsane Olakorede, Erta Beqiri, Giada Cucciolini, Virginia Motroni, Claudia Ann Smith, Marina Sandra Cherchi, Ronan O'Leary, Peter Smielewski

Physiological Reports · 2025-04 · 13 (8)

DOI: 10.14814/phy2.70332 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physiological Reports, online erschienen am 17.04.2025. Verfasst von Stefan Yu Bögli und 8 weiteren Autor:innen. Beteiligte Einrichtung: Brain Physics Laboratory, Division of Neurosurgery, Department of Clinical Neurosciences, University of Cambridge, Cambridge, UK. Hauptthemen laut MEDLINE: Cerebrovascular Circulation, Homeostasis, Brain Injuries, Traumatic. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Swiss National Science Foundation, Cambridge Trust CIS Scholarship, Medical Research Council and Gates Cambridge Scholarship.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A bstract Cerebrovascular autoregulation (CAR) maintains stable cerebral perfusion by adjusting arteriole diameters in response to slow pressure fluctuations. Various CAR correlation coefficients—PRx (based on intracranial pressure—ICP), Mx (based on transcranial doppler—TCD), and COx/THx (based on near‐infrared spectroscopy—NIRS)—are used interchangeably despite fundamental differences. 566 hours of ICP, NIRS, and TCD data from 38 traumatic brain injury (TBI) patients were assessed. The intercorrelation between CAR correlation coefficients was compared in relation to: (1) The impact of different filtering methods (to minimize noise); (2) The impact of slow wave power (i.e., magnitude of incoming trigger); (3) The impact of coherence (i.e., to what extent can the power of slow waves explain the change in power within the cerebral biosignal). Only coherence stratification consistently increased the metric intercorrelation to PRx (high vs. low) when evaluating Mx (0.43 vs. 0.08, p < 0.01) and THx (0.36 vs. 0.05, p < 0.01). Additionally, high coherence and ABP power were associated with fewer correlation coefficients around 0. Coherence increases the intercorrelation between the different CAR metrics. These sections might be regarded as more reliable, since they are derived from different biosignals that are all affected by CAR through different mechanisms.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cerebrovascular CirculationHomeostasisBrain Injuries, TraumaticHumansMaleAdultFemaleUltrasonography, Doppler, TranscranialMiddle AgedSpectroscopy, Near-InfraredIntracranial PressureYoung Adult

Stichwörter der Autor:innen

cerebrovascular autoregulationintensive caremultimodality monitoringtraumatic brain injury

Autor:innen und Institutionen

  • Brain Physics Laboratory, Division of Neurosurgery, Department of Clinical Neurosciences, University of Cambridge, Cambridge, UK.
  • Department of Neurology and Neurocritical Care Unit, Clinical Neuroscience Center, University Hospital Zurich, University of Zurich, Zurich, Switzerland.
  • Department of Surgical, Medical, Molecular Pathology and Critical Care Medicine, University of Pisa, Pisa, Italy.
  • Departmental Structure of Neuroanesthesia and Critical Care, Azienda Ospedaliero-Universitaria Pisana, Pisa, Italy.
  • Department of Critical Care, Marques de Valdecilla University Hospital, and Biomedical Research Institute (IDIVAL), Santander, Cantabria, Spain.
  • Neurosciences and Trauma Critical Care Unit, Addenbrooke's Hospital, Cambridge University Hospitals, Cambridge, UK.

ORCID-Profile: Stefan Yu Bögli

Förderung

  • Swiss National Science Foundation
  • Cambridge Trust CIS Scholarship
  • Medical Research Council and Gates Cambridge Scholarship
  • Patrick and Margaret Flanagan Skye Cambridge Trust Scholarship
  • Cantabrian Health Service
  • Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung

Zitieren

APA

Bögli, S. Y., Olakorede, I., Beqiri, E., Cucciolini, G., Motroni, V., Smith, C. A., Cherchi, M. S., O'Leary, R., & Smielewski, P. (2025). Untangling discrepancies between cerebrovascular autoregulation correlation coefficients: An exploration of filters, coherence and power. Physiological Reports, 13(8). https://doi.org/10.14814/phy2.70332

Vancouver

Bögli SY, Olakorede I, Beqiri E, Cucciolini G, Motroni V, Smith CA, et al. Untangling discrepancies between cerebrovascular autoregulation correlation coefficients: An exploration of filters, coherence and power. Physiological Reports. 2025;13(8). doi:10.14814/phy2.70332

BibTeX
@article{Bgli2025,
  author = {Bögli, Stefan Yu and Olakorede, Ihsane and Beqiri, Erta and Cucciolini, Giada and Motroni, Virginia and Smith, Claudia Ann and Cherchi, Marina Sandra and O'Leary, Ronan and Smielewski, Peter},
  title = {Untangling discrepancies between cerebrovascular autoregulation correlation coefficients: An exploration of filters, coherence and power},
  journal = {Physiological Reports},
  year = {2025},
  volume = {13},
  number = {8},
  doi = {10.14814/phy2.70332}
}