EUVIMEDEUVIMED entdecken
CrossrefInfokarte

Nursing Strategies and Safety Devices for Preventing Parenteral Therapy–‎Related Iatrogenesis in Low- And Middle-Income Countries: A Scoping Review

Qudus Bayonle Olayiwola, Hazanah Adebola Suleiman, Ogooluwa Joshua Agboola, Mubarak Ademola Egbinola, Zainab Moyosore Ayanwale, Nurudeen Ajadi Gbamigbola, Rukayat Ebudola Fatai, Oluwatobi ‎Deborah Ayodeji, Praise Olatide Oki, Olamide Arkofgod Oki, Demilade Sarah Olaniyi

International Journal of Advanced Nursing Studies · 2026

DOI: 10.14419/dz8dbw05 ↗
AbstractBibliografische Angaben

Abstract

Background: Parenteral therapy is a high-risk component of clinical care because injectable and ‎infused medicines bypass physiological barriers, enabling rapid harm when errors occur. In low- ‎and middle-income countries [LMICs], these risks may be intensified by staffing constraints, ‎limited device availability, weak reporting systems, and inconsistent infection prevention ‎infrastructure.‎ Objective: This scoping review mapped evidence on parenteral therapy–related iatrogenic risks, ‎safety devices, and medication administration technologies, and nursing and system-level ‎determinants of safer parenteral therapy implementation in LMICs.‎ Methods: A scoping review was conducted in accordance with PRISMA-ScR guidance. ‎PubMed/MEDLINE, Scopus, Web of Science, and CINAHL were searched for English-language ‎publications from 2010 to 2026. Additional sources were identified through citation searching, ‎professional guidance, and relevant reference lists. 71 studies met the inclusion criteria; 68 were ‎mapped to one or more review objectives, while 3 studies supported methodological, conceptual, ‎or background framing. Evidence was synthesized using narrative synthesis and evidence ‎mapping, guided by the SEIPS socio-technical systems framework.‎ Results: The review found that Iatrogenesis spanned all clinical phases, including preparation ‎errors, glass particulate contamination, wrong infusion rates, catheter-related infections, and unsafe ‎injection practices. These risks were exacerbated by heavy workloads and workflow interruptions. ‎Safety devices addressed specific vulnerabilities: prefilled syringes reduced preparation complexity; ‎filters mitigated particulate exposure; smart pumps reduced programming errors; and ‎BCMA/eMAR systems strengthened verification. However, technology effectiveness depended on ‎training, usability, workflow integration, procurement reliability, and institutional support.‎ Conclusion: Preventing parenteral therapy–related iatrogenesis in LMICs requires layered, ‎context-sensitive implementation combining nursing competence, standardized protocols, robust ‎infection prevention, safety devices, and organizational governance.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →