EUVIMEDEUVIMED entdecken
Crossref

Experimental study on the broad-spectrum high-precision wavelength calibration and power stability of MG-Y lasers

Chenxi Yang, Yi Fu, Guangxiang Wu, Zhangwei Tong, Yanfeng Yang, Wencheng Li, Shuxiang Song, Jun Yang

Optics Continuum · 15.11.2026 · 5 (11) · 3583

DOI: 10.1364/optcon.609451 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Optics Continuum, online erschienen am 02.11.2026. Verfasst von Chenxi Yang und 7 weiteren Autor:innen. Die Arbeit nennt 15 Literaturangaben. Gefördert von: Guangxi Regional Innovation Capability Enhancement Plan Project, Central Guiding Local Science and Technology Development Fund Projects.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Modulated grating Y-branch (MG-Y) tunable lasers feature a broad tuning range, high side-mode suppression ratio (SMSR), and fast response speed, and have become core light sources for fiber-optic sensing, high-precision spectral analysis, and fiber Bragg grating (FBG) demodulation systems. However, the strong nonlinear coupling among multi-channel driving currents, wavelength drift, and mode competition brings challenges to simultaneous optimization of wavelength precision and output power in full-spectrum operation. To address these issues, this paper proposes a phased progressive calibration strategy for MG-Y lasers. Firstly, full-range scanning of left and right grating currents is implemented to collect raw datasets. Eleven linear correlation models between dual-grating currents are established via data visualization and least-squares fitting. Typical current operating points are selected by analyzing the nonlinear relationship between wavelength and right grating current. On this basis, phase current scanning is optimized and invalid data points are eliminated to construct a high-precision current-wavelength lookup table (LUT), which covers the spectral range of 1527.6–1568.4 nm with a fixed wavelength interval of 16 pm. Finally, closed-loop regulation of the semiconductor optical amplifier (SOA) and phase current is adopted to realize wavelength fine-tuning and power flattening. Experimental results demonstrate that the maximum wavelength deviation of the established LUT is less than 1 pm, the output power is stabilized at 12.1 dBm with slight fluctuation, and the SMSR remains above 40 dB across the full tuning band. The proposed method possesses a smooth tuning trajectory and outstanding repeatability. This approach greatly simplifies the LUT generation procedure and achieves a good balance between technical performance and engineering practicability. It can provide a stable and high-precision light source for high-end FBG demodulation and spectral measurement applications.

Förderung

  • Guangxi Regional Innovation Capability Enhancement Plan Project
  • Central Guiding Local Science and Technology Development Fund Projects

Zitieren

APA

Yang, C., Fu, Y., Wu, G., Tong, Z., Yang, Y., Li, W., Song, S., & Yang, J. (2026). Experimental study on the broad-spectrum high-precision wavelength calibration and power stability of MG-Y lasers. Optics Continuum, 5(11), 3583. https://doi.org/10.1364/optcon.609451

Vancouver

Yang C, Fu Y, Wu G, Tong Z, Yang Y, Li W, et al. Experimental study on the broad-spectrum high-precision wavelength calibration and power stability of MG-Y lasers. Optics Continuum. 2026;5(11):3583. doi:10.1364/optcon.609451

BibTeX
@article{Yang2026,
  author = {Yang, Chenxi and Fu, Yi and Wu, Guangxiang and Tong, Zhangwei and Yang, Yanfeng and Li, Wencheng and Song, Shuxiang and Yang, Jun},
  title = {Experimental study on the broad-spectrum high-precision wavelength calibration and power stability of MG-Y lasers},
  journal = {Optics Continuum},
  year = {2026},
  volume = {5},
  number = {11},
  pages = {3583},
  doi = {10.1364/optcon.609451}
}
Kostenlos starten →