EUVIMEDEUVIMED entdecken
CrossrefInfokarte

Intra-abdominal pressure in children receiving peritoneal dialysis for acute kidney injury

Peter Nourse, Mignon McCulloch, Ashton Coetzee, Timothy Bunchman, Stefano Picca, Jody Rusch, Andre Brooks, Hilton Heydenrych, Brenda Morrow

Peritoneal Dialysis International: Journal of the International Society for Peritoneal Dialysis · 2026-07-29

DOI: 10.1177/08968608261472553 ↗
AbstractBibliografische Angaben

Abstract

Background Critically ill children on peritoneal dialysis (PD) are at an increased risk of raised intra-abdominal pressure (IAP). The aim of this study was to describe IAP and complications with a standard PD fill volume, using conventional PD and continuous flow PD (CFPD) in critically ill children with acute kidney injury. A secondary objective was to compare two IAP measurement techniques, which were direct measurement from the PD catheter via a manometer and indirect measurement via the bladder catheter to a transducer. Method This study was a secondary analysis of a previously published randomized controlled crossover trial. Within- and between-group changes in IAP, blood pressure and ventilation parameters were analysed using paired t-tests. Bland–Altman and intraclass correlation tests were used to assess agreement between direct and intravesicular measurement of IAP. Results Fifteen participants (median (range) age and weight 6.0 (0.2–14) months and 5.8 (2.3–14.0) kg) were included, of which 9 (60%) had raised IAP (>10 mmHg) after filling. No children developed compartment syndrome or other complications. Mean ± standard deviation IAP on conventional versus CFPD was 9.35 ± 2.97 and 11.5 ± 2.96 versus 9.3 ± 3.35 and 11.2 ± 3.62 when measured directly and indirectly, respectively ( p > 0.5). Intravesicular measurement of IAP was constantly significantly higher compared to the direct method ( p = 0.002); however, there was good correlation (Pearson correlation coefficient 0.7; p < 0.001) and moderate reliability (ICC = 0.6) between the methods. Conclusion Increased IAP (>10 mmHg) was common, although not associated with serious adverse events, and warrants monitoring in these patients. The pressures measured are different with the two techniques used, although they do correlate well. More studies are needed to define increased IAP depending on the measuring technique and inform IAP measurement practice in children with acute PD.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →