EUVIMEDEUVIMED entdecken
CrossrefInfokarte

Accuracy Assessment of Human and Artificial Intelligence-Assisted Bitewing Radiography and Near-Infrared Reflectance Imaging-Based Methods for Interproximal Caries Detection: A Histological Validation

Nicole Rodrigues, Francisco Martinez-Rus, Alicia Miguel-Calvo, Guillermo Pradíes, Maria Paz Salido

Caries Research · 2025-05-30 · 60 (2) · 173-184

DOI: 10.1159/000546644 ↗
AbstractBibliografische Angaben

Abstract

Introduction: This study compared the diagnostic accuracy of interproximal caries detection using intraoral bitewing radiographs, assessed by both human operators and an artificial intelligence (AI) program, a near-infrared reflectance imaging (NIRI) system with operator-conducted assessment, and histological evaluation as the reference. Methods: 100 posterior teeth with or without caries were mounted on 10 typodonts. Initially, 180 surfaces were examined, but eight were excluded for different reasons. Therefore, 171 proximal surfaces were analyzed. NIRI imaging was performed using the iTero Element 5D®, and radiographs were analyzed by operators and an AI program, Denti.AI. Results were compared with histology, assessing sensitivity (Se), specificity (Sp), positive (PPV) and negative (NPV) predictive values, F1-score, areas under receiver operating characteristic curves (AUCs), and the Fleiss Kappa coefficient (k). Results: The statistical analysis results for each diagnostic test were as follows: examiner radiographic assessment (Se = 52%, Sp = 84.6%, PPV = 71.6%, NPV = 70.3%, F1-score = 60%, AUC = 0.684, k = 0.459); NIRI (Se = 37%, Sp = 98.9%, PPV = 96.4%, NPV = 67.8%, F1-score = 52%, AUC = 0.673, k = 0.475); AI-guided radiographic assessment (Se = 13.7%, Sp = 95.9%, PPV = 71%, NPV = 59.8%, F1-score = 23%, AUC = 0.548). McNemar’s test showed a p < 0.05 for all diagnostic tests. Conclusion: Both the operator-conducted NIRI system and examiner radiographic assessment demonstrated superior detection capabilities compared to the AI program. Among these methods, the examiner radiographic assessment yielded the best results, followed by the NIRI system, demonstrating its potential for clinical use.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →