Transbronchial Cryobiopsy Using the Ultrathin 1.1-mm Cryoprobe with Ultrathin Bronchoscopy under Radial Endobronchial Ultrasound Guidance for Diagnosis of Peripheral Pulmonary Lesions
Respiration · 2024
DOI: 10.1159/000538196 ↗Kurz gefasst
Fachartikel in der Zeitschrift Respiration, 2024. Verfasst von Franziska Hasselbring und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pneumology and Critical Care Medicine, Thoraxklinik, University of Heidelberg, Heidelberg, Germany. Hauptthemen laut MEDLINE: Bronchoscopy, Cryosurgery, Lung Neoplasms, Feasibility Studies. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 19 Literaturangaben.
Abstract (Originalsprache)
Introduction
Today, the increasing number of incidentally detected peripheral pulmonary lesions (PPLs) within and outside lung cancer screening trials is a diagnostic challenge. This fact encourages further improvement of diagnostic procedures to increase the diagnostic yield of transbronchial biopsy, which has been shown to have a low complication rate. The purpose of this study was to evaluate the safety and feasibility of a new ultrathin 1.1 cryoprobe that can be placed through an ultrathin bronchoscope (UTB) using fluoroscopy and radial endobronchial ultrasonography (rEBUS) navigation for assessing PPLs.
Methods
Thirty-five patients with PPL less than 4 cm in diameter were prospectively enrolled to receive transbronchial cryobiopsies (TBCBs) using the ultrathin 1.1-mm cryoprobe. Navigation to the PPL was accomplished with the UTB. Under rEBUS and fluoroscopy guidance up to 4 cryobiopsies were obtained. The sample sizes of the biopsies were compared to a historic collective derived from a 1.9-mm cryoprobe and standard forceps. The feasibility and safety of the procedure, the cumulative and overall diagnostic yield, and the cryobiopsy sizes were evaluated.
Results
After detection with the rEBUS, TBCB was collected from 35 PPLs, establishing a diagnosis in 25 cases, corresponding to an overall diagnostic yield of 71.4%. There was no difference in diagnostic yield for PPL <20 mm or ≥20 mm. All cryobiopsies were representative with a mean tissue area of 11.9 ± 4.3 mm2, which was significantly larger compared to the historic collective (p = 0.003). Six mild and four moderate bleeding events and 1 case of pneumothorax were observed.
Conclusions
Using the ultrathin 1.1-mm cryoprobe combined with an UTB for rEBUS-guided TBCB of PPL is feasible and safe. This diagnostic approach improves bronchoscopic techniques for diagnosing peripheral lung lesions and may contribute to improve diagnosis of lung cancer even in small PPL.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Pneumology and Critical Care Medicine, Thoraxklinik, University of Heidelberg, Heidelberg, Germany.
- Translational Lung Research Center Heidelberg (TLRC-H), Member of the German Center for Lung Research (DZL), Heidelberg, Germany.
- Department of General Pathology, Institute of Pathology, Heidelberg University Hospital, Heidelberg, Germany.
- Centre of Histology, Cytology and Molecular Pathology, Wiesbaden, Germany.
- Department of Hematology, Oncology, and Rheumatology, Heidelberg University Hospital, Heidelberg, Germany.
- Laborarztpraxis Rhein-Main MVZ GbR, Frankfurt am Main, Germany.
Zitieren
APA
Hasselbring, F., Herth, F. J. F., Kriegsmann, M., Kriegsmann, K., & Eberhardt, R. (2024). Transbronchial Cryobiopsy Using the Ultrathin 1.1-mm Cryoprobe with Ultrathin Bronchoscopy under Radial Endobronchial Ultrasound Guidance for Diagnosis of Peripheral Pulmonary Lesions. Respiration. https://doi.org/10.1159/000538196
Vancouver
Hasselbring F, Herth FJF, Kriegsmann M, Kriegsmann K, Eberhardt R. Transbronchial Cryobiopsy Using the Ultrathin 1.1-mm Cryoprobe with Ultrathin Bronchoscopy under Radial Endobronchial Ultrasound Guidance for Diagnosis of Peripheral Pulmonary Lesions. Respiration. 2024. doi:10.1159/000538196
BibTeX
@article{Hasselbring2024,
author = {Hasselbring, Franziska and Herth, Felix J F and Kriegsmann, Mark and Kriegsmann, Katharina and Eberhardt, Ralf},
title = {Transbronchial Cryobiopsy Using the Ultrathin 1.1-mm Cryoprobe with Ultrathin Bronchoscopy under Radial Endobronchial Ultrasound Guidance for Diagnosis of Peripheral Pulmonary Lesions},
journal = {Respiration},
year = {2024},
doi = {10.1159/000538196}
}
EUVIMED