EUVIMEDEUVIMED entdecken
CrossrefInfokarte

Quantitative Synthesis of CO 2 Fixation Rates and Indoor Air Pollutant Removal by Microalgae: A Systematic Review and Meta‐Analysis

Yonca Yaman, Ayça Tokuç, Tunahan Akış, Yaşar Onur Demiral, Azize Ayol, Gizem Tuna Tuygun, Mehmet Akif Ezan, Irem Deniz

Indoor Air · 2026-01 · 2026 (1)

DOI: 10.1155/ina/1291972 ↗
AbstractBibliografische Angaben

Abstract

Poor indoor air quality (IAQ) is linked to premature deaths, respiratory diseases, reduced cognitive function, increased energy costs, and diminished well‐being. Although traditional air filtration and ventilation systems are common, microalgae‐based systems are emerging as a sustainable alternative. This systematic review and meta‐analysis provide pooled quantitative estimates of microalgae CO 2 fixation rates for IAQ applications. In accordance with PRISMA guidelines, 46 studies from the Web of Science and Scopus databases were included in the qualitative synthesis. Thirteen comparisons reporting quantitative CO 2 fixation rates were analyzed using a random‐effects meta‐analysis with DerSimonian–Laird method and publication bias assessment through a funnel plot and Egger′s regression test. To the authors′ knowledge, this is the first meta‐analysis of microalgae CO 2 fixation rates for IAQ application providing pooled estimates and evaluating pollutant removal efficiency, microalgae species, and building integration strategies. The pooled CO 2 fixation rate was 99.77 mg/L/day (95% CI: 80.09–119.46), with rates ranging from 90.59 mg/L/day for Spirulina sp. to 156.70 mg/L/day for Scenedesmus sp. For building‐integrated applications, the ambient subgroup estimate of 35.09 mg/L/day (95% CI 26.43–43.75) is the recommended design benchmark, although experiments under optimized laboratory conditions achieve removal rates of 80%–99% CO 2 , up to 100% volatile organic compounds (VOCs), 55.42%–98% of particulate matter (PM 2.5 ) and 66%–95% of carbon monoxide (CO), nitrogen monoxide (NO), and nitrogen dioxide (NO 2 ). Although the variability among studies limits broader applicability, these findings enable informed system sizing and species selection criteria for building applications. Pilot‐scale and standardized research is essential for advancing these technologies. This review is registered with OSF and supported by the Research Fund of Dokuz Eylul University.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →