Β eyond Relaxation: What CO 2 Levels Reveal About Indoor Air Quality in Greek SPA Facilities During COVID‐19?
Indoor Air · 2026-01 · 2026 (1)
DOI: 10.1155/ina/1138130 ↗Abstract
Aim Post‐pandemic, CO 2 measurements are widely used as indirect indicators of ventilation adequacy and serve as a complement to indoor air quality (IAQ) assessment. IAQ in spa facilities can be affected by airborne contaminants released by humans and by products commonly used in these facilities. This study aims to assess IAQ characteristics (carbon dioxide, relative humidity, temperature, oxygen levels, and nitrogen oxides) in hotel spa centers in an island region of Greece, and to examine the influence of operational and architectural characteristics, including building floor levels, occupancy density, and ventilation types. Subjects and Methods Environmental monitoring took place in 103 spa centers throughout the island. The studied parameters included CO 2 and CO concentrations, as well as NO and NO 2 and O 2 concentrations, temperature, and relative humidity. CO 2 concentration was used as a complementary environmental marker of ventilation sufficiency and space occupancy. These short (~3 min) single‐point measurements were collected using portable calibrated equipment during the spa’s regular schedule. Differences in Δ CO 2 by floor level, window status, and occupancy tier were tested with ANOVA and nonparametric tests. Results The mean Δ CO₂ was 391.3 ppm (maximum 600 ppm), corresponding to a mean absolute indoor CO₂ of approximately 791 ppm (range approximately 700–1000 ppm) assuming a fixed outdoor reference of 400 ppm; 28 of 103 sites (27.2%) exceeded 800 ppm. Mean temperature was 24.5°C (11 sites above 26°C), and mean relative humidity was 65.6% (maximum 79.5%; 52 sites above 65%). CO, NO, and NO₂ readings were at or below instrument resolution and are indicative only, while oxygen remained at atmospheric levels (mean 20.9%). Δ CO₂ did not differ significantly by floor level ( p = 0.93), window status ( p = 0.92), or occupancy tier ( p = 0.46). Conclusions To our knowledge, this is the first large‐scale survey of IAQ in spa facilities in Greece. Within the limits of short, single‐point measurements, most measured parameters were within reference ranges during the COVID‐19 restrictions, whereas mean relative humidity and maximum temperature exceeded them, and CO₂ indicated moderate accumulation of exhaled air. Because air exchange rates were not measured, the results do not establish ventilation effectiveness or safety with respect to airborne infection risk. The study provides a baseline dataset and a rationale for ventilation‐based monitoring and spa‐specific guidance.
EUVIMED