Heavy Metal Toxicity Following Metal‐on‐Metal Knee Arthroplasty Revision Surgery: A Case Report
Case Reports in Orthopedics · 2026-01 · 2026 (1)
DOI: 10.1155/cro/3777088 ↗Abstract
Metallosis is a rare complication; hence, previous investigations regarding this topic are restricted to case reports. Little has been published on metallosis following total knee arthroplasty (TKA). We report the case of a patient who experienced cobalt and chromium metallosis 14 years following TKA‐revision surgery. She developed a variety of symptoms that could indicate systemic clinical toxicity, including skin redness, headaches, irritability, cognitive decline, and sleep disturbances. Replacing the prosthesis, utilizing chelation therapy, and trials of double‐filtration plasmapheresis reduced the serum level of heavy metals upon regular laboratory follow‐ups, leading to a temporary relief of symptoms. The presence of confounding factors and other concomitant conditions makes the distinction between systemic metal exposure and suspected systemic clinical toxicity very challenging.