Blood Density Is Nearly Equal to Water Density: A Validation Study of the Gravimetric Method of Measuring Intraoperative Blood Loss

Dominic J. Vitello, Richard M. Ripper, Michael R. Fettiplace, Guy L. Weinberg, Joseph M. Vitello

Journal of Veterinary Medicine · 2015-01-29 · 2015 · 1-4

DOI: 10.1155/2015/152730 ↗
AbstractBibliografische Angaben

Abstract

Purpose . The gravimetric method of weighing surgical sponges is used to quantify intraoperative blood loss. The dry mass minus the wet mass of the gauze equals the volume of blood lost. This method assumes that the density of blood is equivalent to water (1 gm/mL). This study’s purpose was to validate the assumption that the density of blood is equivalent to water and to correlate density with hematocrit. Methods . 50 µ L of whole blood was weighed from eighteen rats. A distilled water control was weighed for each blood sample. The averages of the blood and water were compared utilizing a Student’s unpaired, one-tailed t -test. The masses of the blood samples and the hematocrits were compared using a linear regression. Results . The average mass of the eighteen blood samples was 0.0489 g and that of the distilled water controls was 0.0492 g. The t -test showed P = 0.2269 and R 2 = 0.03154 . The hematocrit values ranged from 24% to 48%. The linear regression R 2 value was 0.1767. Conclusions . The R 2 value comparing the blood and distilled water masses suggests high correlation between the two populations. Linear regression showed the hematocrit was not proportional to the mass of the blood. The study confirmed that the measured density of blood is similar to water.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →