Evaluating the Use of a Negative D-Dimer and Modified Low Wells Score in Excluding above Knee Deep Venous Thrombosis in an Outpatient Population, Assessing Need for Diagnostic Ultrasound
ISRN Radiology · 2014
DOI: 10.1155/2014/519875 ↗Abstract
Aims . Colour doppler ultrasonography (CDUS) is widely used in the diagnosis of deep venous thrombosis (DVT); however, the number of scans positive for above knee DVT is low. The present study evaluates the reliability of the D-dimer test combined with a clinical probability score (Wells score) in ruling out an above knee DVT and identifying patients who do not need a CDUS. Materials and Method . This study is a retrospective audit and reaudit of a total of 816 outpatients presenting with suspected lower limb DVT from March 2009 to March 2010 and from September 2011 to February 2012. Following the initial audit, a revised clinical diagnostic pathway was implemented. Results . In our initial audit, seven patients (4.9%) with a negative D-dimer and a low Wells score had a DVT. On review, all seven had a risk factor identified that was not included in the Wells score. No patient with negative D-dimer and low Wells score with no extra clinical risk factor had a DVT on CDUS (negative predictive value 100%). A reaudit confirmed adherence to our revised clinical diagnostic pathway. Conclusions . A negative D-dimer together with a low Wells score and no risk factors effectively excludes a lower limb DVT and an ultrasound is unnecessary in these patients.