A simple voltage‐modulated Markov chain model for the Piezo1 ion channel to investigate electromechanical pacing
The Journal of Physiology · 2026
DOI: 10.1113/jp288666 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Physiology, 2026. Verfasst von Dennis Ogiermann und 3 weiteren Autor:innen. Beteiligte Einrichtung: Chair of Continuum Mechanics, Ruhr University Bochum, Universitätsstraße 150, Bochum, Germany. Hauptthemen laut MEDLINE: Ion Channels, Myocytes, Cardiac. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 91 Literaturangaben. Gefördert von: Deutsche Forschungsgemeinschaft (DFG).
Abstract (Originalsprache)
Piezo1 ion channels are voltage‐modulated, stretch‐activated ion channels involved in a variety of important physiological and pathophysiological processes, as, for example, cardiovascular development and homeostasis. Since their discovery, it has been known that this type of ion channel desensitizes when exposed to stretch. However recent experiments on Piezo1 ion channels have uncovered that their stretch response is qualitatively different when exposed to positive electrochemical driving forces, where the desensitization is reset. In this work we propose a novel voltage‐modulated mathematical model of Piezo1 based on a continuous‐time Markov chain. We show that our Piezo1 model is able to quantitatively reproduce a wide range of experimental observations. Furthermore we integrate our new ion channel model into the Mahajan–Shiferaw ventricular cardiomyocyte model to study the effect of electromechanical pacing at the cellular scale. This integrated cell model is able to qualitatively reproduce some aspects of the experimental observations regarding the rate‐dependence of electromechanical pacing protocols. Our studies suggest that the Piezo1 ion channel is an important component that significantly contributes to the electromechanical coupled response of cardiomyocytes. image Key points PIEZO ion channels are voltage‐modulated, mechanically gated ion channels involved in a large variety of mechanically regulated physiological processes and diseases. Recent experiments on Langendorff‐perfused rabbit hearts by A. Quinn and P. Kohl [2016] suggest a non‐trivial relation between the number of captured mechanical stimuli and the electromechanical pacing protocol. We present a novel thermodynamically consistent in silico model of the Piezo1 ion channel with electromechanical gating that can reproduce a large variety of experimental observations during combined exposure to electrical and mechanical stimuli. The new ion channel model is integrated into the well‐established Mahajan–Shiferaw rabbit ventricular cardiomyocyte model to study its role during normal heart beat and during electromechanical pacing protocols. Our in silico studies suggest that the Piezo1 ion channel alone may not be sufficient to explain the experimental observations made by A. Quinn and P. Kohl.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Chair of Continuum Mechanics, Ruhr University Bochum, Universitätsstraße 150, Bochum, Germany.
- Department of Mechanical and Aerospace Engineering, University of Central Florida, Orlando, Florida, USA.
ORCID-Profile: Dennis Ogiermann, Abdulaziz Mohamed, Luigi E Perotti, Daniel Balzani
Förderung
- Deutsche Forschungsgemeinschaft (DFG)
Zitieren
APA
Ogiermann, D., Mohamed, A., Perotti, L. E., & Balzani, D. (2026). A simple voltage‐modulated Markov chain model for the Piezo1 ion channel to investigate electromechanical pacing. The Journal of Physiology. https://doi.org/10.1113/jp288666
Vancouver
Ogiermann D, Mohamed A, Perotti LE, Balzani D. A simple voltage‐modulated Markov chain model for the Piezo1 ion channel to investigate electromechanical pacing. The Journal of Physiology. 2026. doi:10.1113/jp288666
BibTeX
@article{Ogiermann2026,
author = {Ogiermann, Dennis and Mohamed, Abdulaziz and Perotti, Luigi E and Balzani, Daniel},
title = {A simple voltage‐modulated Markov chain model for the Piezo1 ion channel to investigate electromechanical pacing},
journal = {The Journal of Physiology},
year = {2026},
doi = {10.1113/jp288666}
}
EUVIMED