Fachartikel in der Zeitschrift Xenotransplantation, 2024. Verfasst von Martin Bender und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anaesthesiology, University Hospital, LMU Munich, Munich, Germany. Hauptthemen laut MEDLINE: Transplantation, Heterologous, Pleural Effusion, Papio, Ultrasonography. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: German Research Foundation, Swiss National Science Foundation, Bavarian Research Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Pleural effusions develop frequently after cardiac surgery in humans. Lung ultrasound is an essential non‐invasive tool in the diagnosis and treatment of these effusions. Pleural effusions also develop regularly after preclinical cardiac xenotransplantation experiments. Unlike in the human setting, modern ultrasound devices lack pre‐installed tools for calculating the volume of pleural effusions in baboons. The aim of this study was to analyze ultrasound examinations of pleural effusions after orthotopic pig‐to‐baboon cardiac xenotransplantation experiments in order to develop a formula for calculating the effusion volume based on ultrasound measurements.

Methods

Hearts from seven genetically modified (GGTA1‐KO, hCD46/hTBM transgenic) juvenile pigs were orthotopically transplanted into male baboons. Postoperatively, the baboons were tested regularly for the development of pleural effusions using ultrasound. When thoracocentesis was required, the drained effusion volume (EV) was compared to ultrasound‐derived calculations using various formulas. These calculations were based on measuring the distance between lung and diaphragm at the effusions’ maximum height (H max ). Subsequently, the most promising formula was used to describe the interobserver variability between trained and untrained staff members to predict effusion volumes based on ultrasound measurements.

Results

Ultrasound measurement correlated very strongly with the absolute EV ( r = 0.9156, p < 0.0001), with EV indexed to total body weight ( r = 0.9344, p < 0.0001) and with EV indexed to body surface area (BSA) ( r = 0.9394, p < 0.0001). The ratio between H max and EV increased with total body weight and BSA and also depended on the baboon species. The sonographic measurements taken by an experienced and an inexperienced observer showed only low interobserver variability. A Bland–Altman plot of both observers’ measurements showed an overall bias of –2.39%.

Conclusion

Ultrasound imaging provides a simple and non‐invasive tool for measuring pleural effusion quantity in baboons. This facilitates simple and efficient monitoring even in the hands of untrained personnel and may guide the decision‐making to perform thoracocentesis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Transplantation, HeterologousPleural EffusionPapioUltrasonographyHeart TransplantationAnimalsSwineMaleAnimals, Genetically ModifiedHeterograftsHumans

Stichwörter der Autor:innen

heart transplantationpleural effusionsonographyultrasoundxenotransplantation

Autor:innen und Institutionen

  • Department of Anaesthesiology, University Hospital, LMU Munich, Munich, Germany.
  • Transregional Collaborative Research Center 127, Walter Brendel Centre of Experimental Medicine, LMU Munich, Munich, Germany.
  • Revivicor, Blacksburg, Virginia, USA.
  • Institute of Molecular Animal Breeding and Biotechnology, Gene Center and Department of Veterinary Sciences, LMU Munich, Munich, Germany.
  • Center for Innovative Medical Models (CiMM), LMU Munich, Munich, Germany.
  • Interfaculty Center for Endocrine and Cardiovascular Disease Network Modelling and Clinical Transfer (ICONLMU), LMU Munich, Munich, Germany.

ORCID-Profile: Martin Bender, Bruno Reichart, Eckhard Wolf, Jan-Michael Abicht, Matthias Längin

Förderung

  • German Research Foundation
  • Swiss National Science Foundation
  • Bavarian Research Foundation
  • Leducq Foundation
  • Deutsche Forschungsgemeinschaft
  • Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung
  • Bayerische Forschungsstiftung

Zitieren

APA

Bender, M., Radan, J., Reichart, B., Leuschen, M., Wall, F., Mokelke, M., Neumann, E., Buttgereit, I., Ayares, D., Wolf, E., Brenner, P., Abicht, J. M., & Längin, M. (2024). Ultrasound Assessment of Pleural Effusions After Orthotopic Pig‐to‐Baboon Cardiac Xenotransplantation. Xenotransplantation. https://doi.org/10.1111/xen.70006

Vancouver

Bender M, Radan J, Reichart B, Leuschen M, Wall F, Mokelke M, et al. Ultrasound Assessment of Pleural Effusions After Orthotopic Pig‐to‐Baboon Cardiac Xenotransplantation. Xenotransplantation. 2024. doi:10.1111/xen.70006

BibTeX
@article{Bender2024,
  author = {Bender, Martin and Radan, Julia and Reichart, Bruno and Leuschen, Maria and Wall, Felicia and Mokelke, Maren and Neumann, Elisabeth and Buttgereit, Ines and Ayares, David and Wolf, Eckhard and Brenner, Paolo and Abicht, Jan-Michael and Längin, Matthias},
  title = {Ultrasound Assessment of Pleural Effusions After Orthotopic Pig‐to‐Baboon Cardiac Xenotransplantation},
  journal = {Xenotransplantation},
  year = {2024},
  doi = {10.1111/xen.70006}
}
Kostenlos starten →