EUVIMEDEUVIMED entdecken
CrossrefInfokarte

Cervical articular process joint versus ventral cervical stabilization in horses: A biomechanical study

Machiel P. Ysebaert, Ryan Foslien, Donovan M. David, Andres F. Bonilla, Ben C. Gadomski, Jeremiah T. Easley, Brad B. Nelson

Veterinary Surgery · 2026-11 · 55 (8) · 1340-1353

DOI: 10.1111/vsu.70166 ↗
AbstractBibliografische Angaben

Abstract

Abstract Objective To determine the biomechanical properties and modes of failure of a single level equine cervical spine immobilized with unilateral or bilateral articular process joint (APJ) stabilization, ventral cervical stabilization (VCS) and non‐stabilized controls. Study design Ex vivo experimental study. Sample population A total of 24 equine cadaver cervical spines. Methods Cervical spinal units (C4–C5) were randomly assigned to four groups ( n = 6/group): unilateral APJ stabilization, bilateral APJ stabilization, VCS using pedicle screws and rod constructs, or non‐stabilized. Non‐destructive testing assessed kinematic range of motion (ROM), neutral zone, and stiffness in flexion‐extension, axial rotation, and lateral bending. Specimens underwent four‐point bending to failure (0.1 mm/s). Radiographs and visual inspection characterized failure mode. Groups were compared using one‐way ANOVA or Kruskal‐Wallis tests. Significance was p < .05. Results Non‐destructive testing showed unilateral and bilateral APJ constructs were stiffer in flexion‐extension, axial rotation and lateral bending than non‐stabilized ( p < .05). In destructive testing, bilateral APJ stabilization was 2.5× stiffer than VCS, with similar failure moments. Construct stiffness was higher with bilateral APJ stabilization (27.89 ± 5.11 Nm/°) versus non‐stabilized (6.92 ± 3.90 Nm/°, p = .0037), unilateral APJ (14.06 ± 2.94 Nm/°, p < .0001) and VCS (11.28 ± 3.01 Nm/°, p < .0001) groups. Failure typically occurred as cranial articular process fracture in both bilateral and unilateral APJ constructs. Conclusion Bilateral APJ stabilization demonstrated greater stiffness than VCS with comparable failure moments. Clinical significance Bilateral APJ stabilization, with its higher stiffness than VCS, may be an alternative strategy to achieve spinal fusion in horses while avoiding a ventral surgical approach. Future investigations and development of this technique in vivo are warranted before implementation in clinical cases.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →