EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Biomechanical comparison of the bone‐screw‐fastener to conventional cortical buttress screw in a simulated ex vivo model of equine midbody proximal sesamoid bone fracture repair

Thomas J O'Brien, James W Johnson, Christopher E Kawcak, Ben C Gadomski, Ryan S Carpenter, Brad B Nelson

Veterinary Surgery · 2025

DOI: 10.1111/vsu.70060 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Veterinary Surgery, 2025. Verfasst von Thomas J O'Brien und 5 weiteren Autor:innen. Beteiligte Einrichtung: Orthopedic Research Center, C. Wayne McIlwraith Translational Medicine Institute, Department of Clinical Sciences College of Veterinary Medicine and …. Hauptthemen laut MEDLINE: Bone Screws, Fractures, Bone, Sesamoid Bones, Fracture Fixation, Internal. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: American College of Veterinary Surgeons Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To compare implant failure and gap displacement characteristics of simulated medial mid‐body proximal sesamoid bone (PSB) fractures repaired with bone‐screw‐fasteners (BSF) or cortical screws (CS) in single or double screw configurations. Study design Ex vivo experimental study. Sample population A total of 14 paired equine cadaver forelimbs.

Methods

Medial mid‐body PSB osteotomies were created in each forelimb. Surgical repair was performed using either: (1) single 3.5 mm BSF (BSF single ), (2) single 4.5 mm CS (CS single ), (3) two 3.5 mm BSFs (BSF double ), or (4) two 3.5 mm cortical screws (CS double ) ( n = 7 repairs/group). Biomechanical properties and failure characteristics were evaluated through a single cycle to failure. Comparisons between groups were made using Wilcoxon‐matched pairs or Mann–Whitney tests. Statistical significance was p < .05.

Results

The BSF double group (2081 ± 181 N) had significantly higher yield than BSF single (1458 ± 92 N, p = .01) and CS single (1532 ± 86 N, p = .02) groups. The CS double group (2101 ± 126 N) had significantly higher yield than BSF single ( p = .001) and CS single ( p = .003) groups. Biomechanical properties were not different between BSF single and CS single groups, or between BSF double and CS double groups. Gap measurements at construct failure were significantly higher abaxially than axially in all groups (all p < .05).

Conclusion

No differences were detected between the single BSF and 4.5 mm CS for repair of medial mid‐body PSB fractures. Surgical repair using two screws has biomechanical advantage to single screw repair, regardless of screw type ex vivo. Clinical significance The BSF is not different to CS for repair of PSB fractures. Counteracting abaxial forces in surgical repair of mid‐body PSB fractures warrants further investigation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Bone ScrewsFractures, BoneSesamoid BonesFracture Fixation, InternalAnimalsHorsesBiomechanical PhenomenaCadaverForelimb

Autor:innen und Institutionen

  • Orthopedic Research Center, C. Wayne McIlwraith Translational Medicine Institute, Department of Clinical Sciences College of Veterinary Medicine and Biomedical Sciences, Colorado State University, Fort Collins, Colorado…
  • Department of Mechanical Engineering, Orthopedic Bioengineering Research Laboratory, Colorado State University, Fort Collins, Colorado, USA.
  • Equine Medical Center, Cypress, California, USA.

Förderung

  • American College of Veterinary Surgeons Foundation

Zitieren

APA

O'Brien, T. J., Johnson, J. W., Kawcak, C. E., Gadomski, B. C., Carpenter, R. S., & Nelson, B. B. (2025). Biomechanical comparison of the bone‐screw‐fastener to conventional cortical buttress screw in a simulated ex vivo model of equine midbody proximal sesamoid bone fracture repair. Veterinary Surgery. https://doi.org/10.1111/vsu.70060

Vancouver

O'Brien TJ, Johnson JW, Kawcak CE, Gadomski BC, Carpenter RS, Nelson BB. Biomechanical comparison of the bone‐screw‐fastener to conventional cortical buttress screw in a simulated ex vivo model of equine midbody proximal sesamoid bone fracture repair. Veterinary Surgery. 2025. doi:10.1111/vsu.70060

BibTeX
@article{OBrien2025,
  author = {O'Brien, Thomas J and Johnson, James W and Kawcak, Christopher E and Gadomski, Ben C and Carpenter, Ryan S and Nelson, Brad B},
  title = {Biomechanical comparison of the bone‐screw‐fastener to conventional cortical buttress screw in a simulated ex vivo model of equine midbody proximal sesamoid bone fracture repair},
  journal = {Veterinary Surgery},
  year = {2025},
  doi = {10.1111/vsu.70060}
}
Kostenlos starten →