Proximal femoral fixation method and axial load affect simulated muscle forces in an ex vivo feline limb press

Parisa Mazdarani iD, Michelle B M Nielsen iD, James E Miles iD

Veterinary Surgery · 2025

DOI: 10.1111/vsu.14252 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary Surgery, 2025. Verfasst von Parisa Mazdarani und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Veterinary Clinical Sciences, University of Copenhagen, Copenhagen, Denmark. Hauptthemen laut MEDLINE: Muscle, Skeletal, Femur, Femoral Fractures, Fracture Fixation, Internal. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To quantify how increasing axial loads combined with different femoral fixation methods impact simulated quadriceps and gastrocnemius muscle forces. Study design Experimental, non‐randomized, ex vivo study.

Methods

A custom limb press permitting axial loads of 10%–40% bodyweight with three femoral fixation models was tested with 24 limbs from 12 cats (4 per method). Fixation models were: one–complete hip mobility, two–rigid femoral fixation, three–flexion‐extension hip mobility. Femoral angulation to horizontal of 60° ±5° and stifle/hock angulations of 120° ±5° were maintained using turnbuckles. Primary outcomes were bodyweight normalized quadriceps and gastrocnemius forces, and their ratio. Secondary outcomes were radiographic limb angulation and relative foot position for models 2 and 3.

Results

Normalized quadriceps forces increased more with axial load in models 1 and 3 than model 2 ( p = .04), whereas normalized gastrocnemius force increased more with model 2 than models 1 and 3 ( p = .009). Force ratios were unaffected by axial load ( p = .4), but model 2 ratios were lower than models 1 and 3 ( p = .007). Femoral angulation did not differ with load ( p = .1) or model ( p = .9), but both stifle and hock flexed with increasing load ( p < .001) but remained largely within target. Relative foot position was mean 3.9 mm more caudal in model 2 than model 3.

Conclusion

Simulated muscle forces were proportionate to axial load, while rigid femoral fixation negatively affected both forces and ratios. Clinical significance Retaining hip flexion‐extension yields normalized quadriceps forces closer to in vivo values and could improve current ex vivo models.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Muscle, SkeletalFemurFemoral FracturesFracture Fixation, InternalAnimalsCatsBiomechanical PhenomenaWeight-BearingHindlimb

Autor:innen und Institutionen

  • Department of Veterinary Clinical Sciences, University of Copenhagen, Copenhagen, Denmark.

ORCID-Profile: Parisa Mazdarani, Michelle B M Nielsen, James E Miles

Zitieren

APA

Mazdarani, P., Nielsen, M. B. M., & Miles, J. E. (2025). Proximal femoral fixation method and axial load affect simulated muscle forces in an ex vivo feline limb press. Veterinary Surgery. https://doi.org/10.1111/vsu.14252

Vancouver

Mazdarani P, Nielsen MBM, Miles JE. Proximal femoral fixation method and axial load affect simulated muscle forces in an ex vivo feline limb press. Veterinary Surgery. 2025. doi:10.1111/vsu.14252

BibTeX
@article{Mazdarani2025,
  author = {Mazdarani, Parisa and Nielsen, Michelle B M and Miles, James E},
  title = {Proximal femoral fixation method and axial load affect simulated muscle forces in an ex vivo feline limb press},
  journal = {Veterinary Surgery},
  year = {2025},
  doi = {10.1111/vsu.14252}
}
Kostenlos starten →