EUVIMEDEUVIMED entdecken
EvaluationsstudieOpen Access · CC BY-NC 4.0

In vitro evaluation of a hybrid negative pressure system for wound therapy

Jack S Davey iD, Wye Li Chong iD, Jake Fountain iD, Jane Heller iD, Rui Sul iD, Kieri Jermyn iD, Jacob Michelsen iD, Louisa Ho Eckart iD

Veterinary Surgery · 2024

DOI: 10.1111/vsu.14101 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Veterinary Surgery, 2024. Verfasst von Jack S Davey und 7 weiteren Autor:innen. Beteiligte Einrichtung: Animal Referral Hospital Canberra, Pialligo, Australian Capital Territory, Australia. Hauptthemen laut MEDLINE: Negative-Pressure Wound Therapy. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

The objective of this study was to assess whether negative pressure could be maintained accurately and repeatably with a wall‐suction‐based hybrid negative pressure wound therapy (h‐NPWT) system by comparing it with a commercial negative pressure wound therapy (NPWT) device. Study design In vitro experimental study.

Methods

A commercial NPWT device (control) and three h‐NPWT devices, with 0, 3, and 6 meters of additional tubing using the hospital‐wall suction (groups 1, 2, and 3 respectively), were applied sequentially to a commercial NPWT dressing on a silicone skin substrate and set to run at a continuous pressure of −125 mmHg. The pressure within the wound space was monitored at 10 second intervals for 24 h. The process was repeated five times for each group.

Results

The commercial NPWT device produced an average pressure variance of 3.02 mmHg, and the h‐NPWT produced average variances of 4.38, 4.24 and 4.20 mmHg for groups 1, 2 and 3, respectively. All groups produced an average pressure within 0.15 mmHg of −125 mmHg over the 24‐hour period, and the h‐NPWT systems produced the smallest range with all values remaining within a ±5% variation from −125 mmHg.

Conclusion

The h‐NPWT system achieved negative pressures that were comparable to those of a commercial control NPWT device. The addition of tubing between the skin substrate and the canister did not affect the pressure applied at the wound site. Clinical significance The h‐NPWT device tested in this study can be considered as an alternative for negative wound therapy when a commercial device cannot be used.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Negative-Pressure Wound TherapyAnimalsWound HealingIn Vitro TechniquesBandages

Autor:innen und Institutionen

  • Animal Referral Hospital Canberra, Pialligo, Australian Capital Territory, Australia.
  • School of Agricultural, Environmental and Veterinary Sciences, Faculty of Science and Health, Charles Sturt University, Wagga Wagga, New South Wales, Australia.

ORCID-Profile: Jack S Davey, Wye Li Chong, Jake Fountain, Jane Heller, Rui Sul, Kieri Jermyn, Jacob Michelsen, Louisa Ho Eckart

Zitieren

APA

Davey, J. S., Chong, W. L., Fountain, J., Heller, J., Sul, R., Jermyn, K., Michelsen, J., & Ho Eckart, L. (2024). In vitro evaluation of a hybrid negative pressure system for wound therapy. Veterinary Surgery. https://doi.org/10.1111/vsu.14101

Vancouver

Davey JS, Chong WL, Fountain J, Heller J, Sul R, Jermyn K, et al. In vitro evaluation of a hybrid negative pressure system for wound therapy. Veterinary Surgery. 2024. doi:10.1111/vsu.14101

BibTeX
@article{Davey2024,
  author = {Davey, Jack S and Chong, Wye Li and Fountain, Jake and Heller, Jane and Sul, Rui and Jermyn, Kieri and Michelsen, Jacob and Ho Eckart, Louisa},
  title = {In vitro evaluation of a hybrid negative pressure system for wound therapy},
  journal = {Veterinary Surgery},
  year = {2024},
  doi = {10.1111/vsu.14101}
}
Kostenlos starten →