EUVIMEDEUVIMED entdecken
CrossrefInfokarte

Contrast‐Enhanced Ultrasonography of Orbital and Intraocular Pathologies in 24 Dogs and 6 Cats

Janneke I. Ortner, Katharina M. Hittmair, Barbara Nell, Klaas‐Ole Blohm

Veterinary Ophthalmology · 2026-11 · 29 (6)

DOI: 10.1111/vop.70281 ↗
AbstractBibliografische Angaben

Abstract

ABSTRACT Objective Contrast‐enhanced ultrasonography (CEUS) is a noninvasive and relatively safe imaging technique to assess ocular perfusion, showing high sensitivity and specificity for tumor characterization in human oncology, while reports on its application in canine and feline diseased eyes are limited. This study aimed to describe the CEUS features of orbital and intraocular pathologies in dogs and cats in order to evaluate its diagnostic value in detecting and characterizing various lesions. Animal Studied CEUS examinations of 30 animals (24 dogs, 6 cats) were evaluated retrospectively. Procedures Following B‐mode ultrasonography, CEUS examinations utilizing sulfur hexafluoride were performed. Pathologies were categorized in one of the following groups: orbital neoplastic lesions, orbital inflammatory lesions, intraocular neoplastic lesions, intraocular inflammatory lesions and retinal detachment. Qualitative perfusion parameters, contrast intensity, enhancement pattern, perfusion type and time to wash‐in and wash‐out were evaluated. Results CEUS detected vascularization in orbital and intraocular pathologies, with variable enhancement characteristics. Persistent vascularization was observed in all cases of retinal detachment. In orbital and intraocular neoplastic lesions, CEUS improved lesion localization, assessment of interactions with surrounding tissues and tissue perfusion. For inflammatory pathologies such as abscesses, myositis, and steatitis, the additional diagnostic value of CEUS compared to B‐mode ultrasonography was limited. Conclusion Findings indicated that CEUS could identify a variety of orbital and intraocular pathologies and provided additional diagnostic information to B‐mode ultrasonography, particularly for assessing neoplastic lesions and retinal detachments. CEUS has the potential to enhance ophthalmic ultrasonography in differentiating specific pathologies. Prospective studies are warranted to further evaluate its clinical use.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →