EUVIMEDEUVIMED entdecken
Crossref

Experimentally induced anisometropia thresholds for distance stereoacuity in adults: A psychophysical approach

Emine Tınkır Kayıtmazbatır iD, Adem Ünal iD, Ayşe Bozkurt Oflaz iD, Şule Acar Duyan iD

Ophthalmic and Physiological Optics · 2025

DOI: 10.1111/opo.70012 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Ophthalmic and Physiological Optics, 2025. Verfasst von Emine Tınkır Kayıtmazbatır und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Faculty of Medicine, Selcuk University, Konya, Turkey. Hauptthemen laut MEDLINE: Anisometropia, Depth Perception, Visual Acuity, Vision, Binocular. Die Arbeit nennt 16 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Stereopsis, a critical aspect of binocular vision, can be influenced by refractive errors. This study investigated how experimentally induced anisometropia affected distance stereopsis in adults and aimed to determine threshold levels for different types and amounts of experimentally induced anisometropia.

Methods

Twenty healthy adults (aged 20–45 years) with normal visual acuity and baseline distance stereopsis were included. Distance stereopsis was assessed using the Distance Randot Stereotest at 3 m. Trial lenses inducing myopic, hyperopic and astigmatic anisometropia (axes: 45°, 90° and 180°) were applied over the dominant eye in 0.25 D increments. After each lens placement, a 30‐s adaptation period preceded assessment of stereoacuity. At each disparity level (400, 200, 100 and 60 arc seconds), the minimum anisometropic lens power causing loss of stereoacuity was recorded. As per the test manual, each disparity level included plates A and B, but only B plate responses were analysed, as correct identification was required to proceed.

Results

Experimentally induced myopic anisometropia led to the earliest loss of stereopsis, with a mean threshold of 1.38 D at the 400 arc seconds level. Against‐the‐rule astigmatism exhibited the greatest tolerance, requiring higher refractive errors to degrade stereoacuity ( p < 0.001). At 400 and 200 arc seconds, even low levels of experimentally induced myopic anisometropia (

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AnisometropiaDepth PerceptionVisual AcuityVision, BinocularPsychophysicsSensory ThresholdsHumansAdultFemaleMaleYoung AdultMiddle Aged

Stichwörter der Autor:innen

anisometropiabinocular visiondistance stereopsismyopic anisometropiarefractive errorsstereoacuity

Autor:innen und Institutionen

  • Department of Ophthalmology, Faculty of Medicine, Selcuk University, Konya, Turkey.

ORCID-Profile: Emine Tınkır Kayıtmazbatır, Adem Ünal, Ayşe Bozkurt Oflaz, Şule Acar Duyan

Zitieren

APA

Kayıtmazbatır, E. T., Ünal, A., Oflaz, A. B., & Duyan, Ş. A. (2025). Experimentally induced anisometropia thresholds for distance stereoacuity in adults: A psychophysical approach. Ophthalmic and Physiological Optics. https://doi.org/10.1111/opo.70012

Vancouver

Kayıtmazbatır ET, Ünal A, Oflaz AB, Duyan ŞA. Experimentally induced anisometropia thresholds for distance stereoacuity in adults: A psychophysical approach. Ophthalmic and Physiological Optics. 2025. doi:10.1111/opo.70012

BibTeX
@article{Kaytmazbatr2025,
  author = {Kayıtmazbatır, Emine Tınkır and Ünal, Adem and Oflaz, Ayşe Bozkurt and Duyan, Şule Acar},
  title = {Experimentally induced anisometropia thresholds for distance stereoacuity in adults: A psychophysical approach},
  journal = {Ophthalmic and Physiological Optics},
  year = {2025},
  doi = {10.1111/opo.70012}
}
Kostenlos starten →