EUVIMEDEUVIMED entdecken
CrossrefInfokarte

Artificial intelligence in radiographic quantification and severity assessment of peri‐implant marginal bone loss: A systematic review

Hooman Khanzadeh, Sanaz Azizigermi, Aida Mokhlesi, Rasoul Gheisari, Gülce Çakmak, Pedro Molinero‐Mourelle, Andrea Roccuzzo, Seyed Ali Mosaddad

Journal of Prosthodontics · 2026-09-22

DOI: 10.1111/jopr.70245 ↗
AbstractBibliografische Angaben

Abstract

ABSTRACT Purpose To critically assess artificial intelligence (AI)‐based radiographic models for quantitative measurement, localization/detection, segmentation/keypoints, diagnostic classification, and severity or morphology assessment of peri‐implant marginal bone loss (MBL) and peri‐implantitis‐related bone defects. Methods PubMed/MEDLINE, Scopus, Web of Science, Embase, the Cochrane Library, Google Scholar, and reference lists were searched from inception through August 11, 2026. Eligible original studies evaluated AI‐based radiographic assessment of existing dental implants. Quality Assessment of Diagnostic Accuracy Studies‐3 (QUADAS‐3) was applied at the prespecified estimate level for diagnostic/image‐analysis studies and PROBAST for the prediction‐model study. Results A total of 1485 records were identified, and 17 studies were included. Fourteen reported localization/detection outcomes, six segmentation/keypoint outcomes, 10 severity/morphology outcomes, 12 diagnostic/classification outcomes, and six direct AI–clinician comparisons; categories overlapped. Implant/peri‐implant tissue detection reached precision of 0.977, recall of 0.992, F1 score of 0.984, and mean intersection over union (IoU) of 0.916. Implant segmentation achieved a Dice of 0.986 and IoU of 0.974, whereas downstream peri‐implantitis classification precision was 0.777. Sensitivity across diagnostic/prediction tasks ranged from approximately 66% to 96%. No study reported the complete prespecified absolute MBL measurement‐agreement outcome set. Six studies used explicitly independent multi‐rater reference standards with consensus and/or reported reliability, and none underwent clearly traceable independent multicenter external validation. Conclusions Reported performance is task‐specific and is frequently derived from retrospectively selected, enriched, internally split, or augmented datasets. Current models may support research and carefully supervised radiographic image‐analysis tasks, but none can be recommended for routine clinical use until independent multicenter external validation and prospective studies demonstrate clinically acceptable absolute measurement error and patient‐relevant benefit.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →