EUVIMEDEUVIMED entdecken
CrossrefInfokarte

Randomized comparative crossover clinical study of mechanical and optical behavior, and oral health–related quality of life of CAD‐CAM milled and 3D‐printed complete‐arch implant‐supported interim restorations

Solange Vasquez‐Ramos, Rocío Cascos, Juan Ballesteros‐Martínez, Marta Revilla‐León, Miguel Gómez‐Polo

Journal of Prosthodontics · 2026-08 · 35 (7) · 1021-1030

DOI: 10.1111/jopr.70186 ↗
AbstractBibliografische Angaben

Abstract

Abstract Purpose Clinical evidence regarding 3D‐printed complete arch interim prostheses remains limited. This randomized crossover trial was designed to compare mechanical complications between milled polymethylmethacrylate (PMMA) and a hybrid ceramic 3D‐printed interim restoration and assess mechanical complications, passive fit, optical behavior, and oral health–related quality of life. Materials and Methods Twenty edentulous patients received two complete arch interim prostheses, one milled PMMA and one hybrid ceramic resin 3D‐printed restoration, each used for 3 months in a randomized crossover sequence. Mechanical complications, passive fit, optical parameters (L*, a*, b *, Δ E 00), and oral health–related quality of life were assessed. Paired nonparametric tests, including the Wilcoxon signed‐rank test and McNemar test, were applied (α = 0.05), and risk differences with 95% confidence intervals were calculated. Results Milled PMMA exhibited fewer mechanical complications than 3D‐printed (10% vs. 45%; p = 0.016; risk difference +35.0 percentage points; 95% CI: 9.5–60.5). Passive fit showed no statistically significant differences between materials ( p = 0.500). Mean Δ E 00 did not differ significantly (PMMA 4.68 ± 6.57; 3D‐printed 4.73 ± 4.75; p = 0.243). The 3D‐printed material presented higher L * values at both evaluations ( p < 0.001) and a significant increase in a * over time ( p = 0.008). Both materials improved Oral Health Impact Profile‐14 scores; at 3 months, 3D‐printed prostheses showed slightly lower scores than PMMA ( p = 0.045). Conclusions Milled PMMA showed more favorable mechanical performance. Both materials demonstrated passive fit, stable optical behavior, and improvements in patient‐reported outcomes during the 3‐month period. Trial Registration ClinicalTrials.gov identifier: NCT05958043.

Wissen, das zu Ihrer Arbeit passt.

Vom kostenlosen Einstieg über die persönliche Recherche bis zur vollständigen Research Suite.

Tarife ansehen →

Sind alle Verlagsvolltexte enthalten?

Nein. Bibliografische Nachweise, Abstracts und Volltexte sind unterschiedliche Inhalte. Ob ein Volltext verfügbar ist, hängt von der Quelle, Open Access und Ihren vorhandenen Lizenzen ab. Ein EUVIMED-Tarif ersetzt keine zusätzlichen Verlagsrechte.

Tarife ansehen →