Optimization of PCR for quantification of simian immunodeficiency virus genomic RNA in plasma of rhesus macaques ( M acaca mulatta ) using armored RNA
Journal of Medical Primatology · 2014-02 · 43 (1) · 31-43
DOI: 10.1111/jmp.12088 ↗Abstract
Abstract Introduction Quantification of plasma viral load ( PVL ) is used to monitor disease progression in SIV ‐infected macaques. This study was aimed at optimizing of performance characteristics of the quantitative PCR (q PCR ) PVL assay. Methods The PVL quantification procedure was optimized by inclusion of an exogenous control hepatitis C virus armored RNA (a RNA ), a plasma concentration step, extended digestion with proteinase K , and a second RNA elution step. Efficiency of viral RNA (v RNA ) extraction was compared using several commercial v RNA extraction kits. Various parameters of q PCR targeting the gag region of SIV mac239, SIV smE660, and the LTR region of SIV agm SAB were also optimized. Results Modifications of the SIV PVL q PCR procedure increased v RNA recovery, reduced inhibition and improved analytical sensitivity. The PVL values determined by this SIV PVL q PCR correlated with quantification results of SIV RNA in the same samples using the ‘industry standard’ method of branched‐ DNA (b DNA ) signal amplification. Conclusions Quantification of SIV genomic RNA in plasma of rhesus macaques using this optimized SIV PVL q PCR is equivalent to the b DNA signal amplification method, less costly and more versatile. Use of heterologous a RNA as an internal control is useful for optimizing performance characteristics of PVL q PCR s.