Omnipolar Technology Near Field Versus Fragmentation Signals Mapping at Anatomically Defined Ganglionated Plexi Sites During Cardioneuroablation
Journal of Cardiovascular Electrophysiology · 29.10.2026
DOI: 10.1111/jce.70549 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Cardiovascular Electrophysiology, online erschienen am 29.10.2026. Verfasst von Jean Pierre Jabbour und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, European Georges Pompidou Hospital, Paris, France. Die Arbeit nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Cardioneuroablation (CNA) is an established catheter‐based therapy for refractory vasovagal syncope (VVS), targeting atrial ganglionated plexi (GPs) by radiofrequency ablation. Omnipolar Technology Near Field (OTNF) is a novel automated spectral mapping algorithm integrated within the EnSite X system; its systematic comparison with fragmentation mapping during CNA has not previously been reported.
Objectives
To evaluate the feasibility, safety, and efficacy of a streamlined, imaging‐free anatomically guided CNA approach and to compare real‐time OTNF mapping at three spectral thresholds with fractionation analysis in detecting GPs at anatomically consistent locations.
Methods
Twenty‐six consecutive patients (mean age 43.9 ± 16.4 years; 69% female; ≥ 3 VVS episodes/year) were enrolled prospectively at two French centres. All procedures used an HD Grid catheter for bilateral OTNF and fractionation mapping, followed by sequential ablation of five GP sites. Acute success was defined as heart rate increase > 50% from baseline and blunted atropine response (< 25% increment). Directional discordance between fractionation and OTNF map was assessed by McNemar's exact test.
Results
Acute procedural success was achieved in 22 out of 26 patients (84.6%), with no complications. Mean procedure time was 95.2 ± 20.5 min. CNA produced significant vagal denervation: heart rate increased from 60.2 ± 12.9 to 88.1 ± 18.2 bpm ( p < 0.003), AH interval shortened from 97.6 ± 22.9 to 78.2 ± 21.7 ms ( p = 0.007), Wenckebach cycle length decreased from 441.5 ± 118.9 to 330.0 ms ( p < 0.003) and SNRT decreased from 1235.0 ± 273.7 to 1028.4 ± 235.1 ms ( p = 0.003). At 400 Hz, OTNF showed significantly higher signal positivity than fractionation mapping at the LSGP (concordance 57.7%) and RIGP (concordance 65.4%). At 500 and 600 Hz, no directional asymmetry was detected while concordance remained below 70% at these sites. At a median follow‐up of 20.2 ± 7.6 months, 81% of patients were free from syncope.
Conclusions
A simplified, anatomical CNA approach is safe, feasible, and effective. OTNF and fragmentation signals mapping shows modest concordance at five anatomically consistent GP locations, confirming that those strategies capture partially non‐overlapping electrophysiological information.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, European Georges Pompidou Hospital, Paris, France.
- Department of Cardiology, Clinique du Millénaire, Montpellier, France.
- Department of Cardiology, Regional University Hospital Center, Tours, France.
ORCID-Profile: Jean Pierre Jabbour, Alexandre Bodin
Zitieren
APA
Jabbour, J. P., Bodin, A., Raczka, F., Pons, M., Sportouch, C., & Clementy, N. (2026). Omnipolar Technology Near Field Versus Fragmentation Signals Mapping at Anatomically Defined Ganglionated Plexi Sites During Cardioneuroablation. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.70549
Vancouver
Jabbour JP, Bodin A, Raczka F, Pons M, Sportouch C, Clementy N. Omnipolar Technology Near Field Versus Fragmentation Signals Mapping at Anatomically Defined Ganglionated Plexi Sites During Cardioneuroablation. Journal of Cardiovascular Electrophysiology. 2026. doi:10.1111/jce.70549
BibTeX
@article{Jabbour2026,
author = {Jabbour, Jean Pierre and Bodin, Alexandre and Raczka, Franck and Pons, Maxime and Sportouch, Catherine and Clementy, Nicolas},
title = {Omnipolar Technology Near Field Versus Fragmentation Signals Mapping at Anatomically Defined Ganglionated Plexi Sites During Cardioneuroablation},
journal = {Journal of Cardiovascular Electrophysiology},
year = {2026},
doi = {10.1111/jce.70549}
}
EUVIMED