EUVIMEDEUVIMED entdecken
Fallbericht

Electrical Alternans With Alternating Left Ventricular Apical Ballooning Mimicking Takotsubo Cardiomyopathy in a Patient With Extreme QT Prolongation

Ankavipar Saprungruang iD, Sarin Lekchuensakul iD, Supaluck Kanjanauthai, Apichai Khongphatthanayothin iD

Journal of Cardiovascular Electrophysiology · 11.10.2026

DOI: 10.1111/jce.70501 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Journal of Cardiovascular Electrophysiology, online erschienen am 11.10.2026. Verfasst von Ankavipar Saprungruang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Pediatric Cardiology, Cardiac Center, King Chulalongkorn Memorial Hospital, Thai Red Cross Society, Bangkok, Thailand. Hauptthemen laut MEDLINE: Takotsubo Cardiomyopathy, Long QT Syndrome, Action Potentials, Ventricular Function, Left. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 3 Literaturangaben. Gefördert von: Health Systems Research Institute, Faculty of Medicine, Chulalongkorn University, Rachadapiseksompotch Fund, Faculty of Medicine, Chulalongkorn University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

We report unique and rare findings of coupled electrical and mechanical alternans in a patient with extreme QT prolongation.

Methods

A 5‐year‐old girl with congenital long QT syndrome type 3 developed alternate left ventricular apical ballooning precipitated by mycoplasma pneumonia and azithromycin exposure.

Results

During atrial pacing, electrocardiography showed beat‐to‐beat alternation not only in T‐wave morphology but also in QRS configuration, ST segment, and QT interval. These electrical changes were tightly associated with mechanical alternans: beats with markedly prolonged QT intervals showed normal left ventricular (LV) contraction, whereas beats with shorter QT intervals and ST elevation exhibited LV apical ballooning. Treatment with mexiletine shortened the QT interval, abolished both electrical and mechanical alternans, and restored normal LV function.

Conclusions

Alternate LV apical ballooning mimicking Takosubo cardiomyopathy can be seen in a patient with extreme QT prolongation. These findings probably reflected a functional intraventricular conduction block due to marked spatial heterogeneity of repolarization between the LV base and apex.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Takotsubo CardiomyopathyLong QT SyndromeAction PotentialsVentricular Function, LeftHeart RateHumansFemaleElectrocardiographyChild, PreschoolDiagnosis, DifferentialAnti-Arrhythmia AgentsPredictive Value of TestsTreatment OutcomeCardiac Pacing, ArtificialMexiletineVentricular Dysfunction, LeftCardiac Conduction System Disease

Stichwörter der Autor:innen

Takotsubo cardiomyopathyapical ballooningelectrical alternanslong QT syndrome

Substanzen

Anti-Arrhythmia AgentsMexiletine

Autor:innen und Institutionen

  • Division of Pediatric Cardiology, Cardiac Center, King Chulalongkorn Memorial Hospital, Thai Red Cross Society, Bangkok, Thailand.
  • Division of Pediatric Cardiology, Department of Pediatrics, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.
  • Center of Excellence in Arrhythmia Research Chulalongkorn University, Department of Medicine, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.
  • Department of Pediatrics, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand.
  • Bangkok Heart Hospital, Bangkok General Hospital, Bangkok, Thailand.

ORCID-Profile: Ankavipar Saprungruang, Sarin Lekchuensakul, Apichai Khongphatthanayothin

Förderung

  • Health Systems Research Institute
  • Faculty of Medicine, Chulalongkorn University, Rachadapiseksompotch Fund
  • Faculty of Medicine, Chulalongkorn University

Zitieren

APA

Saprungruang, A., Lekchuensakul, S., Kanjanauthai, S., & Khongphatthanayothin, A. (2026). Electrical Alternans With Alternating Left Ventricular Apical Ballooning Mimicking Takotsubo Cardiomyopathy in a Patient With Extreme QT Prolongation. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.70501

Vancouver

Saprungruang A, Lekchuensakul S, Kanjanauthai S, Khongphatthanayothin A. Electrical Alternans With Alternating Left Ventricular Apical Ballooning Mimicking Takotsubo Cardiomyopathy in a Patient With Extreme QT Prolongation. Journal of Cardiovascular Electrophysiology. 2026. doi:10.1111/jce.70501

BibTeX
@article{Saprungruang2026,
  author = {Saprungruang, Ankavipar and Lekchuensakul, Sarin and Kanjanauthai, Supaluck and Khongphatthanayothin, Apichai},
  title = {Electrical Alternans With Alternating Left Ventricular Apical Ballooning Mimicking Takotsubo Cardiomyopathy in a Patient With Extreme QT Prolongation},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2026},
  doi = {10.1111/jce.70501}
}
Kostenlos starten →