Predictors of Permanent Pacemaker Implantation Following Valve‐in‐Valve Transcatheter Aortic Valve Replacement
Journal of Cardiovascular Electrophysiology · 2025
DOI: 10.1111/jce.70139 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2025. Verfasst von Karol Quelal Analuisa und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota, USA. Hauptthemen laut MEDLINE: Transcatheter Aortic Valve Replacement, Pacemaker, Artificial, Cardiac Pacing, Artificial, Aortic Valve. Die Arbeit nennt 20 Literaturangaben. Gefördert von: The authors received no specific funding for this work..
Abstract (Originalsprache)
Background
Valve‐in‐valve transcatheter aortic valve replacement (ViV‐TAVR) is increasingly used to treat structural valve degeneration. Permanent pacemaker implantation (PPI) following TAVR is associated with increased morbidity and mortality, yet predictors specific to ViV‐TAVR remain poorly defined.
Objective
To identify clinical and procedural predictors of PPI in patients undergoing ViV‐TAVR.
Methods
We conducted a retrospective observational study of consecutive ViV‐TAVR cases at the Mayo Clinic from 2012 to 2022. Clinical, ECG, procedural data and fluoroscopic measurements were analyzed, and propensity score matching was used to adjust for confounding. Predictors of PPI were identified using multivariable logistic regression.
Results
Among 261 patients, 24 (9.2%) underwent PPI. Balloon‐expandable valves were used in 66.7% and self‐expanding valves in 33.3%. Predictors of PPI included Preprocedural bifascicular block (OR 12.15, 95% CI: 2.52–68.89, p = 0.003), greater septal implantation depth (OR 1.29, 95% CI: 1.04–1.65, p = 0.019), and post‐procedural new left (OR 23.56, 95% CI: 4.91–48.52, p = 0.0004) and right bundle branch blocks (OR 24.4, 95% CI: 3.82–30.51, p = 0.001). Aortic regurgitation as the mechanism of prosthetic valve failure was associated with reduced PPI odds (OR 0.28, 95% CI: 0.10–0.76, p = 0.014). Pacing requirement—defined as > 90% ventricular pacing—increased from 25% at 3 months to 56.25% at 12 months. At a median follow‐up of 962.5 days (IQR 481.5–1555.3), adjusted mortality was significantly higher in the PPI group (aOR 9.4, 95% CI: 1.9–60.4, p = 0.028).
Conclusion
Bifascicular block, greater septal depth, and new bundle branch blocks predict PPI post‐ViV‐TAVR, while aortic regurgitation appears protective. Risk stratification and procedural planning are critical.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota, USA.
- Kaiser Permanente San Francisco Medical Center, San Francisco, California, USA.
ORCID-Profile: Karol Quelal Analuisa, Alan M Sugrue, Yong-Mei Cha, Abhishek J Deshmukh
Förderung
- The authors received no specific funding for this work.
Zitieren
APA
Quelal Analuisa, K., Arya, N., Donisan, T., Harmon, D., Alkhouli, M., Sugrue, A. M., Cha, Y. M., Mackram, E. F., & Deshmukh, A. J. (2025). Predictors of Permanent Pacemaker Implantation Following Valve‐in‐Valve Transcatheter Aortic Valve Replacement. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.70139
Vancouver
Quelal Analuisa K, Arya N, Donisan T, Harmon D, Alkhouli M, Sugrue AM, et al. Predictors of Permanent Pacemaker Implantation Following Valve‐in‐Valve Transcatheter Aortic Valve Replacement. Journal of Cardiovascular Electrophysiology. 2025. doi:10.1111/jce.70139
BibTeX
@article{QuelalAnaluisa2025,
author = {Quelal Analuisa, Karol and Arya, Namrata and Donisan, Teodora and Harmon, David and Alkhouli, Mohamad and Sugrue, Alan M and Cha, Yong-Mei and Mackram, Eleid F and Deshmukh, Abhishek J},
title = {Predictors of Permanent Pacemaker Implantation Following Valve‐in‐Valve Transcatheter Aortic Valve Replacement},
journal = {Journal of Cardiovascular Electrophysiology},
year = {2025},
doi = {10.1111/jce.70139}
}
EUVIMED