EUVIMEDEUVIMED entdecken
Klinische StudieStudienprotokoll

Durability of Pulmonary Vein Isolation With the Heliostar Radiofrequency Balloon—The Prospective RABAAF Study With Protocol‐Mandated Repeat Electrophysiology Studies

Samuel K Sørensen iD, Lise D Riis-Vestergaard iD, Jacob Tønnesen iD, Arne Johannessen iD, René Worck iD, Kristian Eskesen iD, German Bertolo iD, Maria Mayorga iD, Martin A Haugdal, Martin H Ruwald iD, Morten L Hansen iD, Jim Hansen iD

Journal of Cardiovascular Electrophysiology · 2025

DOI: 10.1111/jce.70010 ↗

Kurz gefasst

Klinische Studie in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2025. Verfasst von Samuel K Sørensen und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Copenhagen University Hospital Gentofte, Hellerup, Denmark. Hauptthemen laut MEDLINE: Atrial Fibrillation, Cardiac Catheters, Catheter Ablation, Electrophysiologic Techniques, Cardiac. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 27 Literaturangaben. Gefördert von: This study was supported by the Gentofte Hospital and Biosense Webster., Gentofte Hospital.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Pulmonary vein isolation (PVI) is the cornerstone in atrial fibrillation (AF) ablation but achieving durable PVI remains a challenge. The radiofrequency balloon (RFB) is a “single‐shot” ablation catheter for PVI that offers selective energy titration from 10 surface electrodes and 3D mapping system integration. The durability of RFB PVI has not been investigated.

Methods

The objective of this study was to evaluate the durability of RFB PVI by protocol‐mandated remaps in patients with paroxysmal or persistent AF referred for AF ablation at a high‐volume center. RFB procedures were performed under conscious sedation, PVI assessed by high‐density mapping, bidirectional block confirmed after a waiting period of ≥ 20 min, and dormant conduction assessed by adenosine injections. After 4–6 months patients underwent a remap study for assessment of PVI durability by high‐density mapping and assessment of bidirectional block.

Results

Forty‐five patients were enrolled, 43 completed the RFB PVI, and 35/43 (81%) completed the remap study: 26% female, 43% persistent AF, median age 65 (interquartile range: 61–69) years, median CHA 2 DS 2 ‐VASc score 1 (0–2), and median left atrial volume 31 (25–42) mL/m 2 . Acute PVI was achieved in 99% of pulmonary veins (PVs) but focal radiofrequency touch‐up lesions were required in 31% of patients. After 5.4 (4.9–6.1) months, 71% of PVs were durably isolated, and 29% of patients had all PVs durably isolated; 86% of patients were free from documented atrial tachyarrhythmias.

Conclusion

The durability of RFB PVI achieved under conscious sedation was relatively low. However, medium‐term freedom from clinical recurrent arrhythmia was favorable. Trial Registration URL: https://www.clinicaltrials.gov . Unique Identifier: NCT06296888.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Atrial FibrillationCardiac CathetersCatheter AblationElectrophysiologic Techniques, CardiacPulmonary VeinsAgedFemaleHumansMaleMiddle AgedAction PotentialsEquipment DesignHeart RateProspective StudiesRecurrenceTime FactorsTreatment Outcome

Stichwörter der Autor:innen

atrial fibrillationdurabilityelectrophysiological mappingpulmonary vein isolationradiofrequency balloon catheter

Autor:innen und Institutionen

  • Department of Cardiology, Copenhagen University Hospital Gentofte, Hellerup, Denmark.
  • Johnson & Johnson Denmark, Birkerød, Denmark.

ORCID-Profile: Samuel K Sørensen, Lise D Riis-Vestergaard, Jacob Tønnesen, Arne Johannessen, René Worck, Kristian Eskesen, German Bertolo, Maria Mayorga, Martin H Ruwald, Morten L Hansen, Jim Hansen

Förderung

  • This study was supported by the Gentofte Hospital and Biosense Webster.
  • Gentofte Hospital

Zitieren

APA

Sørensen, S. K., Riis-Vestergaard, L. D., Tønnesen, J., Johannessen, A., Worck, R., Eskesen, K., Bertolo, G., Mayorga, M., Haugdal, M. A., Ruwald, M. H., Hansen, M. L., & Hansen, J. (2025). Durability of Pulmonary Vein Isolation With the Heliostar Radiofrequency Balloon—The Prospective RABAAF Study With Protocol‐Mandated Repeat Electrophysiology Studies. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.70010

Vancouver

Sørensen SK, Riis-Vestergaard LD, Tønnesen J, Johannessen A, Worck R, Eskesen K, et al. Durability of Pulmonary Vein Isolation With the Heliostar Radiofrequency Balloon—The Prospective RABAAF Study With Protocol‐Mandated Repeat Electrophysiology Studies. Journal of Cardiovascular Electrophysiology. 2025. doi:10.1111/jce.70010

BibTeX
@article{Srensen2025,
  author = {Sørensen, Samuel K and Riis-Vestergaard, Lise D and Tønnesen, Jacob and Johannessen, Arne and Worck, René and Eskesen, Kristian and Bertolo, German and Mayorga, Maria and Haugdal, Martin A and Ruwald, Martin H and Hansen, Morten L and Hansen, Jim},
  title = {Durability of Pulmonary Vein Isolation With the Heliostar Radiofrequency Balloon—The Prospective RABAAF Study With Protocol‐Mandated Repeat Electrophysiology Studies},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2025},
  doi = {10.1111/jce.70010}
}
Kostenlos starten →