EUVIMEDEUVIMED entdecken
Crossref

Ventricular Arrhythmias Originating From Different Portions of the Anterior Interventricular Vein: Electrocardiographic Characteristics and Ablation Strategy

Zhi-Wei Liu iD, Wu-Ming Hu, Yi-Fan Chen, Wang-An Zhang, Xiao-Wei Li, Jayaseelan Ranichandra Gokuljayanth, Jia-Feng Lin iD, Cheng Zheng iD

Journal of Cardiovascular Electrophysiology · 2025

DOI: 10.1111/jce.16785 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2025. Verfasst von Zhi-Wei Liu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou, China. Hauptthemen laut MEDLINE: Catheter Ablation, Electrocardiography, Tachycardia, Ventricular, Heart Rate. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 15 Literaturangaben. Gefördert von: This study was supported by the National Natural Science Foundation of China [grant numbers 82070333], the Zhejiang Provincial Natural Science Foundation [gran….

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The anterior interventricular vein (AIV) is an important and recognized source of ventricular arrhythmias (VAs) within the coronary venous system. However, no studies have specifically investigated the electrocardiographic (ECG) characteristics and ablation strategies for VAs originating from the AIV.

Objective

This study aimed to investigate the ECG characteristics and optimal ablation strategies for VAs originating from the AIV.

Methods

This study comprised 51 patients with VAs originating from AIV.

Results

The 51 patients were divided into proximal (40 cases) and non‐proximal groups (11 cases) based on their target sites in AIV. Successful ablation was achieved in 82.5% (33/40) patients in the p‐AIV group and 72.7% (8/11) patients in the np‐AIV group. By ECG analysis, we found a deeper S ‐wave in lead I and a lower R ‐wave in lead V1 and V2, indicating a more distal origin in AIV. R I / S I < 0.10, R V2 < 0.325 mV, and R V2 / S V2 < 0.20 were excellent differential indices for predicting VAs originating from the np‐AIV, with the predictive value of 91.3%, 95.1%, and 95.8%, respectively. Ablation modalities, including conventional radiofrequency catheter ablation (RFCA) and guidewire ablation, have been applied in AIV VAs. Among successful cases, 87.8% of VAs were ablated by conventional RFCA and 12.2% by guidewire ablation. In the situation of an acute angle between the AIV and distal great cardiac vein (DGCV) or a thin AIV lumen, guidewire ablation should be prioritized over RFCA.

Conclusion

There were significant differences in the ECG characteristics of VAs at different portions of AIV. Guidewire ablation could be considered an alternative approach for treating AIV‐originated VAs inaccessible to conventional ablation catheters.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Catheter AblationElectrocardiographyTachycardia, VentricularHeart RateCoronary VesselsHumansMaleFemaleMiddle AgedTreatment OutcomeAction PotentialsPredictive Value of TestsAgedRetrospective StudiesAdultElectrophysiologic Techniques, Cardiac

Stichwörter der Autor:innen

anterior interventricular veincatheter ablationelectrocardiographic characteristicsguidewire ablationventricular arrhythmias

Autor:innen und Institutionen

  • Department of Cardiology, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou, China.

ORCID-Profile: Zhi-Wei Liu, Jia-Feng Lin, Cheng Zheng

Förderung

  • This study was supported by the National Natural Science Foundation of China [grant numbers 82070333], the Zhejiang Provincial Natural Science Foundation [gran…

Zitieren

APA

Liu, Z. W., Hu, W. M., Chen, Y. F., Zhang, W. A., Li, X. W., Gokuljayanth, J. R., Lin, J. F., & Zheng, C. (2025). Ventricular Arrhythmias Originating From Different Portions of the Anterior Interventricular Vein: Electrocardiographic Characteristics and Ablation Strategy. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16785

Vancouver

Liu ZW, Hu WM, Chen YF, Zhang WA, Li XW, Gokuljayanth JR, et al. Ventricular Arrhythmias Originating From Different Portions of the Anterior Interventricular Vein: Electrocardiographic Characteristics and Ablation Strategy. Journal of Cardiovascular Electrophysiology. 2025. doi:10.1111/jce.16785

BibTeX
@article{Liu2025,
  author = {Liu, Zhi-Wei and Hu, Wu-Ming and Chen, Yi-Fan and Zhang, Wang-An and Li, Xiao-Wei and Gokuljayanth, Jayaseelan Ranichandra and Lin, Jia-Feng and Zheng, Cheng},
  title = {Ventricular Arrhythmias Originating From Different Portions of the Anterior Interventricular Vein: Electrocardiographic Characteristics and Ablation Strategy},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2025},
  doi = {10.1111/jce.16785}
}
Kostenlos starten →