EUVIMEDEUVIMED entdecken
Multizentrische StudieVergleichsstudie

Comparative Analysis of Leadless Versus Transvenous Pacemakers in Non‐Heart Failure Patients: A Multicenter US Retrospective Study

Michele Fouad, Kerollos Abdelsayed, Shehroze Tabassum, Mohamed Hatem Ellabban iD, Sittinun Thangjui iD, Basel Abdelazeem iD, Sandeep Arora iD

Journal of Cardiovascular Electrophysiology · 2025

DOI: 10.1111/jce.16672 ↗

Kurz gefasst

Multizentrische Studie in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2025. Verfasst von Michele Fouad und 6 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Medicine, Alexandria University, Alexandria, Egypt. Hauptthemen laut MEDLINE: Pacemaker, Artificial, Cardiac Pacing, Artificial, Arrhythmias, Cardiac. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 30 Literaturangaben. Gefördert von: The authors received no specific funding for this work..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Despite leadless pacemakers (LPMs) showing promise, real‐world data comparing them to transvenous pacemakers (TV‐VVI) are insufficient and often contradictory, especially in patients without major comorbidities like heart failure.

Objectives

Comparing LPMs with TV‐VVIs in real‐world patients without HF.

Methods

The TriNetX database (Jan 2015–June 2023) was queried to include adults receiving their first single‐chamber ventricular pacemaker for heart block, bradycardia, sick sinus syndrome, atrial fibrillation, or syncope, excluding those with prior pacemakers, heart failure or enrolled for research settings. Propensity score matching (PSM) was done on 90 covariates. Primary outcomes were assessed after 1 week, 6 months, and 12 months and included mechanical complications, need for re‐intervention, cardiac‐related hemodynamic instability (CRHI), hospitalizations, and mortality. The risk ratio (RR) with a 95% confidence interval (CI) was reported. An E‐sensitivity analysis assessed the impact of unmeasured confounders.

Results

Each group had 1,158 patients after PSM; 58.4% versus 58.9% were males, with mean ages of 74.9 versus 77.4 years. LPMs showed lower mechanical complications at all follow‐up points (RR 0.16, 0.18, 0.21, p < 0.0001). CRHI was lower in the LPM group at 1 week and 6 months (RR 0.72, 0.85, p < 0.05) but higher mortality at 6 and 12 months (RR 1.436, 1.314, p < 0.05). Hospitalization rates and re‐intervention rates were comparable between both groups. The E‐value was satisfactory.

Conclusion

In the absence of HF, LPM was associated with fewer rates of mechanical complications and CRHI. However, late mortality was higher with LPMs. Randomized trials comparing the two devices are crucial.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pacemaker, ArtificialCardiac Pacing, ArtificialArrhythmias, CardiacHumansMaleFemaleRetrospective StudiesAgedUnited StatesTreatment OutcomeTime FactorsRisk FactorsAged, 80 and overDatabases, FactualMiddle AgedEquipment DesignRisk Assessment

Stichwörter der Autor:innen

LPMTV‐VVITriNetXbradyarrhythmialeadlesspacemakersingle‐chambertransvenous

Autor:innen und Institutionen

  • Faculty of Medicine, Alexandria University, Alexandria, Egypt.
  • Heart Rhythm Science Center, Minneapolis Heart Institute Foundation, Minneapolis, Minnesota, USA.
  • Aswan Heart Centre, Magdi Yacoub Foundation, Aswan, Egypt.
  • Department of Medicine, King Edward Medical University, Lahore, Pakistan.
  • Faculty of Medicine, Al-Azhar University, Cairo, Egypt.
  • Department of Cardiology, West Virginia University, Morgantown, West Virginia, USA.

ORCID-Profile: Mohamed Hatem Ellabban, Sittinun Thangjui, Basel Abdelazeem, Sandeep Arora

Förderung

  • The authors received no specific funding for this work.

Zitieren

APA

Fouad, M., Abdelsayed, K., Tabassum, S., Ellabban, M. H., Thangjui, S., Abdelazeem, B., & Arora, S. (2025). Comparative Analysis of Leadless Versus Transvenous Pacemakers in Non‐Heart Failure Patients: A Multicenter US Retrospective Study. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16672

Vancouver

Fouad M, Abdelsayed K, Tabassum S, Ellabban MH, Thangjui S, Abdelazeem B, et al. Comparative Analysis of Leadless Versus Transvenous Pacemakers in Non‐Heart Failure Patients: A Multicenter US Retrospective Study. Journal of Cardiovascular Electrophysiology. 2025. doi:10.1111/jce.16672

BibTeX
@article{Fouad2025,
  author = {Fouad, Michele and Abdelsayed, Kerollos and Tabassum, Shehroze and Ellabban, Mohamed Hatem and Thangjui, Sittinun and Abdelazeem, Basel and Arora, Sandeep},
  title = {Comparative Analysis of Leadless Versus Transvenous Pacemakers in Non‐Heart Failure Patients: A Multicenter US Retrospective Study},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2025},
  doi = {10.1111/jce.16672}
}
Kostenlos starten →