EUVIMEDEUVIMED entdecken
Crossref

Visualization of Electrophysiologically Defined Superior Vena Cava‐Right Atrium Junction With High‐Resolution Mapping Using Atrial Extrastimulus

Masahiro Ishikura, Yoshiaki Kawase, Taiji Miyake, Hitoshi Matsuo

Journal of Cardiovascular Electrophysiology · 2025

DOI: 10.1111/jce.16659 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2025. Verfasst von Masahiro Ishikura und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Gifu Heart Center, Gifu, Japan. Hauptthemen laut MEDLINE: Vena Cava, Superior, Heart Atria, Electrophysiologic Techniques, Cardiac, Action Potentials. Die Arbeit nennt 9 Literaturangaben. Gefördert von: The authors received no specific funding for this work..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Recent studies have identified diagonal conduction block lines at the electrophysiologically defined superior vena cava (SVC)‐right atrium (RA) junction using three‐dimensional mapping systems and reported the utility of SVCI using these lines. However, these block lines are not always observed, requiring the use of a conventional horizontal isolation approach.

Objective

This study aimed to visualize the electrophysiologically defined SVC‐RA junction using high‐resolution mapping with atrial extrastimulus pacing.

Methods

Twenty‐five patients underwent high‐resolution mapping during sinus rhythm (Sinus map) and extrastimulus pacing (S2 map) using a three‐dimensional mapping system (CARTO 3, version 8). Slow conduction or conduction block along the SVC‐RA junction was assessed by adjusting the lower threshold cut‐off value in the “early meets late” analysis. The length of slow or conduction block lines was compared between the two maps.

Results

The S2 map revealed significantly longer slow or conduction block lines compared to the Sinus map (52.5 ± 18.0 mm vs. 35.6 ± 16.1 mm, p = 0.0013). The adjusted lower threshold values were comparable between the two maps: 26.4 ± 3.7% for the S2 map and 25.2 ± 3.8% for the Sinus map ( p = 0.2819). In the S2 map, a slow or block line covering more than half of the junction was observed in all patients. Furthermore, the sinus node was consistently located inferior to this line.

Conclusion

High‐resolution mapping with atrial extrastimulus pacing more clearly visualizes the SVC‐RA junction, potentially enabling more effective SVCI and estimation of the sinus node location.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Vena Cava, SuperiorHeart AtriaElectrophysiologic Techniques, CardiacAction PotentialsHeart RateAtrial FibrillationHumansMaleFemaleMiddle AgedPredictive Value of TestsAgedCardiac Pacing, ArtificialImaging, Three-DimensionalTime Factors

Stichwörter der Autor:innen

ablationatrial fibrillationhigh‐resolution mappingsuperior vena cavasuperior vena cava isolation

Autor:innen und Institutionen

  • Department of Cardiology, Gifu Heart Center, Gifu, Japan.

Förderung

  • The authors received no specific funding for this work.

Zitieren

APA

Ishikura, M., Kawase, Y., Miyake, T., & Matsuo, H. (2025). Visualization of Electrophysiologically Defined Superior Vena Cava‐Right Atrium Junction With High‐Resolution Mapping Using Atrial Extrastimulus. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16659

Vancouver

Ishikura M, Kawase Y, Miyake T, Matsuo H. Visualization of Electrophysiologically Defined Superior Vena Cava‐Right Atrium Junction With High‐Resolution Mapping Using Atrial Extrastimulus. Journal of Cardiovascular Electrophysiology. 2025. doi:10.1111/jce.16659

BibTeX
@article{Ishikura2025,
  author = {Ishikura, Masahiro and Kawase, Yoshiaki and Miyake, Taiji and Matsuo, Hitoshi},
  title = {Visualization of Electrophysiologically Defined Superior Vena Cava‐Right Atrium Junction With High‐Resolution Mapping Using Atrial Extrastimulus},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2025},
  doi = {10.1111/jce.16659}
}
Kostenlos starten →