EUVIMEDEUVIMED entdecken
VergleichsstudieMultizentrische StudieOpen Access · CC BY 4.0

Comparison of Clinical Outcomes Between Left Bundle Branch Area Pacing With a Stylet‐Driven Lead and Conventional Right Ventricular Pacing

Kyung-Yeon Lee, Jinsun Park, JungMin Choi, Hyo-Jeong Ahn, Soonil Kwon, Myung-Jin Cha iD, Jun Kim, Gi-Byoung Nam iD, Kee-Joon Choi iD, Eue-Keun Choi iD, Seil Oh iD, Min Soo Cho iD und 1 weitere

Journal of Cardiovascular Electrophysiology · 2025

DOI: 10.1111/jce.16648 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2025. Verfasst von Kyung-Yeon Lee und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine, Seoul National University Hospital, Seoul, Republic of Korea. Hauptthemen laut MEDLINE: Ventricular Function, Right, Cardiac Pacing, Artificial, Heart Failure, Bundle of His. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: The authors received no specific funding for this work..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Backgrounds and Aims Left bundle branch area pacing (LBBAP) has been shown to reduce the risk of pacing‐facilitated heart failure (HF) compared to right ventricular pacing (RVP), but limited data exists comparing LBBAP with stylet‐driven leads (SDL) and conventional RVP. The study aims to compare clinical outcomes between LBBAP using SDL and conventional RVP.

Methods

From December 2018 to December 2023, patients who underwent pacemaker implantation at two tertiary hospitals were enrolled. Exclusions included those requiring cardiac resynchronization therapy and patients with ventricular pacing burden ≤ 10%. LBBAP was performed using SDL (Solia S60, Biotronik) with a fixed curve delivery sheath. Composite outcome I consisted of HF admission, pacing‐induced cardiomyopathy (defined as an LVEF decline of ≥ 10% or below 50%), and upgrade to biventricular pacing. Composite outcome II included all‐cause death in addition to the components of composite outcome I.

Results

A total of 738 patients (mean age 72.1 years; 52% of men; 243 LBBAP vs. 495 RVP) were included. Atrioventricular block was more common pacing indication in LBBAP group than RVP group (88.1% vs. 69.3%, p < 0.001). Compared to RVP group, ventricular pacing burden was higher in the LBBAP group (96% vs. 86%, p < 0.001). LBBAP was associated with a lower risk of composite outcome I and II compared to RVP (adjusted HR 0.27 [95% confidence interval 0.11–0.68], p = 0.006 for composite outcome I, aHR 0.41 [0.20–0.84], p = 0.015 for composite outcome II), mainly driven by a lower risk of pacing‐induced cardiomyopathy by 70%. There were no significant differences in procedure‐related complications.

Conclusion

LBBAP with SDL was associated with a lower risk of adverse clinical outcomes compared to conventional RVP in patients requiring substantial ventricular pacing.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ventricular Function, RightCardiac Pacing, ArtificialHeart FailureBundle of HisVentricular Function, LeftHumansMaleFemaleAgedTreatment OutcomeRisk FactorsTime FactorsAged, 80 and overRetrospective StudiesRisk AssessmentMiddle AgedHeart RateAction PotentialsCardiomyopathiesRecovery of FunctionEquipment Design

Stichwörter der Autor:innen

conduction system pacing left bundle branch area pacingright ventricular pacingstylet‐driven lead

Autor:innen und Institutionen

  • Department of Internal Medicine, Seoul National University Hospital, Seoul, Republic of Korea.
  • Division of Cardiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
  • Division of Cardiology, Department of Internal Medicine, SMG-SNU Boramae Medical Center, Seoul, Republic of Korea.
  • Department of Internal Medicine, Seoul National University College of Medicine, Seoul, Republic of Korea.

ORCID-Profile: Myung-Jin Cha, Gi-Byoung Nam, Kee-Joon Choi, Eue-Keun Choi, Seil Oh, Min Soo Cho, So-Ryoung Lee

Förderung

  • The authors received no specific funding for this work.

Zitieren

APA

Lee, K. Y., Park, J., Choi, J., Ahn, H. J., Kwon, S., Cha, M. J., Kim, J., Nam, G. B., Choi, K. J., Choi, E. K., Oh, S., Cho, M. S., & Lee, S. R. (2025). Comparison of Clinical Outcomes Between Left Bundle Branch Area Pacing With a Stylet‐Driven Lead and Conventional Right Ventricular Pacing. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16648

Vancouver

Lee KY, Park J, Choi J, Ahn HJ, Kwon S, Cha MJ, et al. Comparison of Clinical Outcomes Between Left Bundle Branch Area Pacing With a Stylet‐Driven Lead and Conventional Right Ventricular Pacing. Journal of Cardiovascular Electrophysiology. 2025. doi:10.1111/jce.16648

BibTeX
@article{Lee2025,
  author = {Lee, Kyung-Yeon and Park, Jinsun and Choi, JungMin and Ahn, Hyo-Jeong and Kwon, Soonil and Cha, Myung-Jin and Kim, Jun and Nam, Gi-Byoung and Choi, Kee-Joon and Choi, Eue-Keun and Oh, Seil and Cho, Min Soo and Lee, So-Ryoung},
  title = {Comparison of Clinical Outcomes Between Left Bundle Branch Area Pacing With a Stylet‐Driven Lead and Conventional Right Ventricular Pacing},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2025},
  doi = {10.1111/jce.16648}
}
Kostenlos starten →