EUVIMEDEUVIMED entdecken
Vergleichsstudie

Efficacy and Safety of High‐Power Short‐Duration Ablation for Cavo‐Tricuspid Isthmus With a Flexible‐Tip Temperature‐Controlled Power Regulation Catheter Performed by Electrophysiology Trainees

Hidehiro Iwakawa iD, Masateru Takigawa iD, Kosuke Nakada, Tasuku Yamamoto, Takashi Ikenouchi, Mayumi Masumura, Miho Negishi, Iwanari Kawamura, Kentaro Goto, Takatoshi Shigeta iD, Takuro Nishimura, Tomomasa Takamiya iD und 5 weitere

Journal of Cardiovascular Electrophysiology · 2025

DOI: 10.1111/jce.16516 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2025. Verfasst von Hidehiro Iwakawa und 16 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Medicine, Tokyo Medical and Dental University, Tokyo, Japan. Hauptthemen laut MEDLINE: Catheter Ablation, Tricuspid Valve, Cardiac Catheters, Education, Medical, Graduate. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: This study (ex-vivo section) was partially supported by JSPS Grants-in-Aid for Scientific Research (22K16068)..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The suitability of high‐power short‐duration (HPSD) cavo‐tricuspid isthmus ablation (CTI‐Abl) for electrophysiology (EP) trainees, as well as the underlying mechanisms of its efficacy, remain unknown. The aim of this study was to clarify the efficacy and safety of HPSD CTI‐Abl performed by EP trainees and assess lesion characteristics between HPSD and moderate‐power long duration (MPLD) ablations.

Methods

Study 1: CTI‐Abl was performed by first‐ to fourth‐year EP trainees in consecutive 113 patients (67 ± 11 years, 27.2% female). Study cohort was historically divided into three groups: MPLD (30–35 W for up to 30 s) using TactiCath (TC‐MPLD, N = 38) and MPLD and HPSD (50 W for 12 s) using TactiFlex (TF‐MPLD, N = 23; TF‐HPSD, N = 52). Primary endpoint was first‐pass bidirectional isthmus block (BIB). Study 2: lesion geometries created by each ablation strategy were compared using an ex‐vivo model.

Results

Study 1: TF‐HPSD ablation strategy demonstrated a higher success rate of first‐pass BIB than MPLD protocol (TC‐MPLD, 58%; TF‐MPLD, 48%; TF‐HPSD, 94%, p < 0.001), without any complications. TF‐HPSD group was associated with shorter total procedure and RF application times, as well as fewer ablation points and gaps, compared to the MPLD groups. Study 2: TF‐HPSD created greater lesion surface length, width, and area than MPLD strategies.

Conclusion

HPSD CTI‐Abl performed by EP trainees using TactiFlex SE catheter demonstrated a higher first‐pass BIB rate, shorter total procedure and RF application times, and fewer ablation points and gaps compared to the conventional method, without increasing complication rates.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Catheter AblationTricuspid ValveCardiac CathetersEducation, Medical, GraduateCardiac ElectrophysiologyAtrial FibrillationHumansFemaleMaleTreatment OutcomeTime FactorsMiddle AgedAgedAction PotentialsEquipment DesignClinical CompetenceHeart RateElectrophysiologic Techniques, Cardiac

Stichwörter der Autor:innen

ablation catheteratrial fluttercatheter ablationcavo‐tricuspid isthmushigh‐power short‐duration

Autor:innen und Institutionen

  • Department of Cardiovascular Medicine, Tokyo Medical and Dental University, Tokyo, Japan.
  • Department of Cardiovascular Medicine, Akita University Graduate School of Medicine, Akita, Japan.

ORCID-Profile: Hidehiro Iwakawa, Masateru Takigawa, Takatoshi Shigeta, Tomomasa Takamiya, Masahiko Goya, Tetsuo Sasano

Förderung

  • This study (ex-vivo section) was partially supported by JSPS Grants-in-Aid for Scientific Research (22K16068).

Zitieren

APA

Iwakawa, H., Takigawa, M., Nakada, K., Yamamoto, T., Ikenouchi, T., Masumura, M., Negishi, M., Kawamura, I., Goto, K., Shigeta, T., Nishimura, T., Takamiya, T., Tao, S., Miyazaki, S., Goya, M., Watanabe, H., & Sasano, T. (2025). Efficacy and Safety of High‐Power Short‐Duration Ablation for Cavo‐Tricuspid Isthmus With a Flexible‐Tip Temperature‐Controlled Power Regulation Catheter Performed by Electrophysiology Trainees. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16516

Vancouver

Iwakawa H, Takigawa M, Nakada K, Yamamoto T, Ikenouchi T, Masumura M, et al. Efficacy and Safety of High‐Power Short‐Duration Ablation for Cavo‐Tricuspid Isthmus With a Flexible‐Tip Temperature‐Controlled Power Regulation Catheter Performed by Electrophysiology Trainees. Journal of Cardiovascular Electrophysiology. 2025. doi:10.1111/jce.16516

BibTeX
@article{Iwakawa2025,
  author = {Iwakawa, Hidehiro and Takigawa, Masateru and Nakada, Kosuke and Yamamoto, Tasuku and Ikenouchi, Takashi and Masumura, Mayumi and Negishi, Miho and Kawamura, Iwanari and Goto, Kentaro and Shigeta, Takatoshi and Nishimura, Takuro and Takamiya, Tomomasa and Tao, Susumu and Miyazaki, Shinsuke and Goya, Masahiko and Watanabe, Hiroyuki and Sasano, Tetsuo},
  title = {Efficacy and Safety of High‐Power Short‐Duration Ablation for Cavo‐Tricuspid Isthmus With a Flexible‐Tip Temperature‐Controlled Power Regulation Catheter Performed by Electrophysiology Trainees},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2025},
  doi = {10.1111/jce.16516}
}
Kostenlos starten →